SIEMENS
9/108
Siemens D 21.4 · 2017
SIMOTICS main motors
Dimensional drawings
SIMOTICS M-1PH8 asynchronous motors – SH 100 – Forced ventilation
9
■
Dimensional drawings
For motor
Dimensions in mm
(inches)
Shaft
height
Type
IEC
A
AB
B
C
H
HA
HC
HD
HE
HG
K
L
1PH8, type of construction IM B35, forced ventilation
100
1PH8101
160
196
167
43
100
11
198
252
294
276.5
12
449.5
(6.30)
(7.72)
(6.57)
(1.69)
(3.94)
(0.43)
(7.80)
(9.92)
(11.57)
(10.89)
(0.47)
(17.70)
1PH8103
202.5
485
(7.97)
(19.09)
1PH8105
262
544.5
(10.31)
(21.44)
1PH8107
297.5
580
(11.71)
(22.83)
Shaft extension DE
Shaft
height
Type
IEC
LA
LB
M
N
P
S
T
D
DB
E
F
GA
100
1PH8101
16
369.5
215
180
250
14
4
38
M12
80
10
41
(0.63)
(14.55)
(8.46)
(7.09)
(9.84)
(0.55)
(0.16)
(1.50)
(3.15)
(0.39)
(1.61)
1PH8103
405
(15.94)
1PH8105
464.5
(18.29)
1PH8107
500
(19.69)
Ø
D
Ø
N
Ø
K
Ø
S
G_NC01_XX_00673
B
HA
T
A
LB
L
LA
E
HC
HG
HD
H
DB
C
AB
P
ØM
GA
F
1PH810
Connector size 1 for
fan connection
G_NC01_EN_00668
HE
Version with
power connector
Size 1.5
© Siemens AG 2017