SINAMICS S120 drive system
Booksize format
Active Interface Modules in booksize format
7
■
Integration
Connection example for Active Interface Module
The Active Interface Module requires a 24 V DC supply for
operation of the integral fan.
The fan rotates after the 24 V DC supply is applied and can, if
necessary (service life, noise), be disconnected from the Control
Unit over the "Fan off" input. It is only permitted to switch off the
fan when the infeed of the drive system is not operating, other-
wise the Active Interface Module will overheat.
The thermostatic switch installed in the Active Interface Module
is evaluated over the connected Active Line Module.
The power cables between the Active Interface Module and
Active Line Module must be shielded if limit values for inter-
ference suppression are to be complied with. The cable shield
can be routed over the shield connection plate (option) to the
Active Interface Module or Active Line Module.
Depending on the position of the Active Interface Module in the
drive system, additional DRIVE-CLiQ cables may be required.
If it is separately installed next to the left side of the Control Unit
and Active Line Module, no additional DRIVE-CLiQ cables are
required. If the Active Interface Module is placed between the
Control Unit and Active Line Module, the DRIVE-CLiQ cables
supplied with the Active Line Modules are suitable for setting up
a line topology, i.e. Active Line Module and all Motor Modules
in series on one DRIVE-CLiQ line. If the Active Line Module is
connected over a separate DRIVE-CLiQ line, the DRIVE-CLiQ
cable marked with (1) must be ordered. A DRIVE-CLiQ cable
suitable for connection (2) is included in the scope of supply
of the Active Line Module.
For DRIVE-CLiQ cables for different configurations,
see section MOTION-CONNECT connection systems.
Separate Active Interface Module
Active Interface Module integrated in the drive line-up
DC link current
G_D211_EN_00190a
1)
Digital input (DI) or digital output (DO), controlled via Control Unit.
Fan off
24 V
ext.
DCN
DCP
Active Interface
Module
PE
PE
PE
W2 V2 U2
X124
M
+ Temp
-
Temp
X21
DO
CU
W1
V1
U1
L3 L2
T1
T2
X121
3
2
1
4
1
2
3
4
+
+
-
-
1)
+
L1
Active Line Module
G_D211_EN_00191d
Motor
Module
Motor
Module
Active
Interface
Module
Active
Line
Module
Control
Unit
DRIVE-CLiQ
. . .
DRIVE-CLiQ cable between Control Unit and Motor Module
Active Interface Module 16 kW:
0.31 m
Active Interface Module 36 kW:
0.41 m
Active Interface Module 55 kW:
0.60 m
Active Interface Module 80 kW and 120 kW:
0.95 m
Included in scope of supply of Active Line Modules
(1)
(2)
G_D211_EN_00192e
Motor
Module
Motor
Module
Active
Interface
Module
Active
Line
Module
Control
Unit
DRIVE-CLiQ
. . .
(1)
(2)