SIEMENS
7/32
Siemens D 21.4 · 2017
SINAMICS S120 drive system
Booksize format
Active Line Modules in booksize format
7
■
Selection and ordering data
■
Technical specifications
Rated power
Active Line Module
in booksize format
kW (hp)
Article No.
Line voltage 380 ... 480 V 3 AC
16 (18)
6SL3130-7TE21-6AA4
36 (40)
6SL3130-7TE23-6AA3
55 (60)
6SL3130-7TE25-5AA3
80 (100)
6SL3130-7TE28-0AA3
120 (150)
6SL3130-7TE31-2AA3
Description
Article No.
Accessories
Shield connection plate
For Line Modules and Motor Modules in
booksize format with a width of
• 150 mm (5.91 in)
6SL3162-1AF00-0AA1
• 200 mm (7.87 in)
6SL3162-1AH01-0AA0
• 300 mm (11.81 in)
6SL3162-1AH00-0AA0
DC link rectifier adapter
For direct infeed of DC link voltage
• Screw-type terminals 0.5 ... 10 mm
2
For Line Modules and Motor Modules
in booksize format with a width of 50 mm
(1.97 in), 75 mm (2.95 in) and 100 mm
(3.94 in)
6SL3162-2BD00-0AA0
• Screw-type terminals 35 ... 95 mm
2
For Line Modules and Motor Modules in
booksize format with a width of 150 mm
(5.91 in), 200 mm (7.87 in) and 300 mm
(11.81 in)
6SL3162-2BM00-0AA0
DC link adapter
(2 units)
For multi-tier configuration
Screw-type terminals 35 ... 95 mm
2
For all Line Modules and Motor Modules
in booksize format
6SL3162-2BM01-0AA0
Accessories for re-ordering
24 V terminal adapter
For all Line Modules and Motor Modules
in booksize format
6SL3162-2AA00-0AA0
24 V jumper
For connection of the 24 V busbars
(for booksize format)
6SL3162-2AA01-0AA0
Terminal Kit
(Plug-in terminals, DRIVE-CLiQ jumper
(length = module width + 60 mm (2.36 in)),
dust protection blanking plugs)
For DRIVE-CLiQ port
For Active Line Modules with a width of
• 100 mm (3.94 in)
6SL3163-8FD00-0AA0
• 150 mm (5.91 in)
6SL3163-8GF00-0AA0
• 200 mm (7.87 in)
6SL3163-8HH00-0AA0
• 300 mm (11.8 in)
6SL3163-8JM00-0AA0
Warning labels in 30 languages
This label set can be glued over the
standard German or English labels to
provide warnings in other languages.
One set of labels is supplied with the
devices.
One sign in each of the following languages
is provided in each set:
BG, CN, CZ, DE, DK, EE, ES, FI, FR, GB,
GR, HU, IE, IS, IT, JP, KR, LT, LV, MT, NL,
NO, PL, PT, RO, RU, SE, SI, SK, TR
6SL3166-3AB00-0AA0
Dust protection blanking plugs
(50 units)
For DRIVE-CLiQ port
6SL3066-4CA00-0AA0
Active Line Module
in booksize format
6SL3130-7TE...
Line voltage
(up to 2000 m (6562 ft)
above sea level)
380 ... 480 V 3 AC ±10 %
(in operation -15 % <1 min)
Line frequency
47 ... 63 Hz
SCCR
(short-circuit current rating)
65 kA in conjunction with the
recommended Class J fuse, or
circuit breaker according to
UL489 / CSA 22.2 No. 5-02
see recommended line-side
components
Line power factor
• Active mode
-
Fundamental power factor
(cos
ϕ
1
)
1 (factory setting), can be altered by
inputting a reactive current setpoint
-
Total (
λ
)
1 (factory setting)
• Smart Mode
-
Fundamental power factor
>0.96
- Overall
0.65 ... 0.9
Overvoltage category
to EN 60664-1
Class III
DC link voltage
V
d
In Active Mode
, the DC link voltage is
regulated and can be adjusted as a
voltage decoupled from the line
voltage.
In Smart Mode
, the DC link voltage is
kept in proportion to the line voltage
at the mean rectified line voltage
value.
Factory setting for DC link voltage:
380 ... 400 V 3 AC: 600 V
(Active Mode)
400 ... 415 V 3 AC: 625 V
(Active Mode)
416 ... 480 V 3 AC:
1.35 × line voltage (Smart Mode)
1)
Electronics power supply
24 V DC -15 %/+20 %
Radio interference suppression
• Standard (Active Line Module +
Active Interface Module)
Category C3 to EN 61800-3 up to
350 m (1148 ft) total cable length
• With line filter
Category C2 according to
EN 61800-3 up to 350 m (1148 ft)
total cable length
Category C3 according to
EN 61800-3 from 350 m to 1000 m
(1148 ... 3281 ft) total cable length
Type of cooling
Internal air cooling (power units with
increased air cooling by built-in fan)
Permissible ambient and coolant
temperature (air)
during operation for line-side
components, Line Modules and
Motor Modules
0 ... 40 °C (32 ... 104 °F)
without derating,
> 40 ... 55 °C (104 ... 131 °F),
see derating characteristics
Installation altitude
Up to 1000 m (3281 ft) above sea
level without derating,
> 1000 ... 4000 m (3281 ... 13124 ft)
above sea level,
see derating characteristics
Declarations of conformity
CE
(Low Voltage and EMC Directives)
Certificate of suitability
cULus
1)
Active Mode can also be selected if the connected motors are suitable for
> 650 V DC.
© Siemens AG 2017