SIEMENS
8/43
Siemens D 21.4 · 2017
SIMOTICS servomotors
SIMOTICS S synchronous motors for SINAMICS S120
SIMOTICS S-1FK7 High Dynamic – Natural cooling
8
Motor type
(repeated)
Effi-
ciency
1)
Stall
current
Calculated
power
P
calc
5)
SINAMICS S120 Motor Module
Power cable with complete shield
Motor connection (and brake connection)
via power connector
Rated
output
current
2)
Booksize format
Internal air cooling
For other components,
see SINAMICS S120
drive system
η
I
0
at
M
0
Δ
T
=100 K
P
calc
at
M
0
Δ
T
=100 K
I
rated
Power
connector
Cable
cross-
section
3)
Pre-assembled
cable
%
A
kW (hp)
A
Article No.
Size
mm
2
Article No.
Line voltage 380 ... 480 V 3 AC
1FK7064-4CC71-...
93
8.1
2.5 (3.35)
9
6SL3120-
7
TE21-0AD.
1
4
×
1.5
6FX
7
002-5
7
N06-
....
1FK7085-4CC71-...
92
13.5
4.6 (6.17)
18
6SL3120-
7
TE21-8AD.
1
4
×
1.5
6FX
7
002-5
7
N06-
....
1FK7086-4CC71-...
93
13.2
5.9 (7.91)
18
6SL3120-
7
TE21-8AD.
1
4
×
1.5
6FX
7
002-5
7
N06-
....
1FK7044-4CF71-...
91
4.0
1.4 (1.88)
5
6SL3120-
7
TE15-0AD.
1
4
×
1.5
6FX
7
002-5
7
N06-
....
1FK7061-4CF71-...
93
6.1
2 (2.68)
9
6SL3120-
7
TE21-0AD.
1
4
×
1.5
6FX
7
002-5
7
N06-
....
1FK7064-4CF71-...
93
10.8
3.8 (5.10)
18
6SL3120-
7
TE21-8AD.
1
4
×
1.5
6FX
7
002-5
7
N06-
....
1FK7085-4CF71-...
92
22.0
6.9 (9.25)
30
6SL3120- 1TE23-0AD.
1.5
4
×
4
6FX
7
002-5
7
N46-
....
1FK7086-4CF71-...
93
21.5
8.8 (11.8)
30
6SL3120- 1TE23-0AD.
1.5
4
×
4
6FX
7
002-5
7
N46-
....
1FK7043-4CH71-...
90
4.1
1.6 (2.15)
5
6SL3120-
7
TE15-0AD.
1
4
×
1.5
6FX
7
002-5
7
N06-
....
1FK7044-4CH71-...
91
5.4
2.1 (2.82)
9
6SL3120-
7
TE21-0AD.
1
4
×
1.5
6FX
7
002-5
7
N06-
....
1FK7061-4CH71-...
93
8.7
3 (4.02)
9
6SL3120-
7
TE21-0AD.
1
4
×
1.5
6FX
7
002-5
7
N06-
....
1FK7064-4CH71-...
93
15.0
5.7 (7.64)
18
6SL3120-
7
TE21-8AD.
1
4
×
1.5
6FX
7
002-5
7
N06-
....
1FK7033-4CK71-...
88
2.1
0.8 (1.07)
3
6SL3120-
7
TE13-0AD.
1
4
×
1.5
6FX
7
002-5
7
N06-
....
1FK7043-4CK71-...
90
5.6
2.2 (2.95)
9
6SL3120-
7
TE21-0AD.
1
4
×
1.5
6FX
7
002-5
7
N06-
....
Power cable:
MOTION-CONNECT 800PLUS
MOTION-CONNECT 500
8
5
Without brake cores
With brake cores
4)
C
D
Length code
....
For information on the cables, refer to
MOTION-CONNECT connection systems
Motor Module:
Single Motor Module
Double Motor Module
1
2
Version status
1)
Optimum efficiency in continuous duty.
2)
With default setting of the pulse frequency.
3)
The current carrying capacity of the power cables complies with EN 60204-1 for installation type C, for continuous duty at an ambient air temperature of
40 °C (104 °F).
4)
Cable cross-section for brake connection 2 × 1.5 mm
2
.
5)
P
[kW] =
9550
calc
M
[Nm]
⋅
n
rated
0
5250
calc
M
[lb
f
-ft]
⋅
n
0
rated
P
[hp] =
© Siemens AG 2017