SIEMENS
8/34
Siemens D 21.4 · 2017
SIMOTICS servomotors
SIMOTICS S synchronous motors for SINAMICS S120
SIMOTICS S-1FK7
8
■
Options
-Z
must be added to the Article No. to order a motor with options.
N24
Reinforced brake
When option "Reinforced brake" is selected for S-1FK7 motors,
they are fitted with a holding brake that is stronger than the
standard brake (cf. built-in holding brakes).
The option "Reinforced brake" is available for the following
S-1FK7 motors:
•
1FK703.-2
....
-
....
;
•
1FK704.-2
....
-
....
; 1FK704.-3
....
-
....
;
•
1FK706.-2
....
-
....
; 1FK706.-3
....
-
....
;
•
1FK708.-2
....
-
....
; 1FK708.-3
....
-
....
; 1FK7086-4
....
-
....
;
•
1FK7101-2
....
-
....
; 1FK7101-3
....
-
....
;
•
1FK7103-2
....
-
....
; 1FK7103-3
....
-
....
;
•
1FK7105-2
....
-
....
; 1FK7105-3
....
-
....
;
Note:
Check whether the mechanical components of the customer's
machine are capable of withstanding increased forces and
torques in the event of an Emergency Off scenario before using
motors with a reinforced brake.
M03
Version for potentially explosive atmospheres Zone 2
in accordance with IEC 60079-15
Combustible or potentially explosive gases or vapors occur only
rarely or briefly in Zone 2 areas. This type of protection is
designated as EEx nA II (non sparking).
The special conditions for operating S-1FK7 motors in Zone 2
areas, in particular the reduction in permissible operating
speeds, are described in detail in Annex 610.40089.01 to the
EC Declaration of Conformity 664.20038.02.
M39
Version for potentially explosive atmospheres Zone 22
in accordance with IEC 61241-1
Combustible or potentially explosive dust (non-conductive dust)
occurs only rarely or briefly in Zone 22 areas. This type of
protection is designated as Ex 3D T 160 °C (320 °F).
The special conditions for operating S-1FK7 motors in Zone 22
areas are described in detail in Annex 610.40090.01 to the
EC Declaration of Conformity 664.20039.02.
Note regarding M03 and M39 options:
It is not
always permissible to combine the option for potentially
explosive atmospheres with other motor options. Please refer to
the configuration manual for further information.
A version with a DRIVE-CLiQ interface on the motor is only
possible for DQI encoders with RJ45 connector. DQ encoders
with SMI cannot be combined with option M03 or M39.
Order code
Description
J..
Mounting of SP+ planetary gearbox
(see SIMOTICS S geared motors)
M03
Version for potentially explosive atmospheres Zone 2 in
accordance with EN 50021/IEC 60079-15
M39
Version for potentially explosive atmospheres Zone 22 in
accordance with EN 50281/IEC 61241-1
N05
Alternative shaft geometry
N16
Version for increased chemical resistance
N24
Reinforced brake
1)
Q31
Metal rating plate instead of adhesive label
V..
Mounting of planetary gearbox LP+
(see SIMOTICS S geared motors)
Paint finish
K23
Special paint finish for "Worldwide" climate group:
Primer and paint finish: Anthracite RAL 7016
1)
K23
+
X..
Special paint finish for "Worldwide" climate group:
Primer and other paint finish can be selected from
X01 to X27
K24
Primer (without paint finish)
2)
X01
Paint finish: Jet black, matt RAL 9005
3)
X02
Paint finish: Cream white RAL 9001
3)
X03
Paint finish: Reseda green RAL 6011
3)
X04
Paint finish: Pebble grey RAL 7032
3)
X05
Paint finish: Sky blue RAL 5015
3)
X06
Paint finish: Pale ivory RAL 1015
3)
X08
Paint finish: Suitable for food grade applications
White aluminum RAL 9006
3)
X27
Paint finish: Dark pearl grey RAL 9023
3)
1)
For the option "Reinforced brake", a brake-version 1FK7 motor must be
ordered with B or H in the 15th data position.
2)
For the primer, the 1FK702 motors must be ordered with 0 or 2 in the 16th
data position.
3)
For the paint finish, the 1FK702 motors must be ordered with 3 or 5 on the
16th data position.
© Siemens AG 2017