SIEMENS
7/283
Siemens D 21.4 · 2017
SINAMICS S120 drive system
Supplementary system components
TM15 Terminal Module
7
■
Integration
The TM15 Terminal Module can communicate with the following
Control Units via DRIVE-CLiQ:
•
CU310-2 Control Unit
•
CU320-2 Control Unit
•
SINUMERIK Control Unit
•
SIMOTION D Control Unit
•
SINAMICS DCM Advanced CUD
Connection example of TM15 Terminal Module
X501
X500
+ 24 V
M
X524
M
+
M
+
M
M
+
M
+
1
0
Terminal Module
TM15
L1+
M1
X520
DI/DO 0
1
2
3
4
5
6
DI/DO 1
DI/DO 3
L1+
DI/DO 2
1)
DI/DO 4
7
8
9
10
DI/DO 5
DI/DO 7
DI/DO 6
M1
L2+
M2
X521
DI/DO 8
1
2
3
4
5
6
DI/DO 9
DI/DO 11
L2+
DI/DO 10
1)
DI/DO 12
7
8
9
10
DI/DO 13
DI/DO 15
DI/DO 14
M2
L3+
M3
X522
DI/DO 16
1
2
3
4
5
6
DI/DO 17
DI/DO 19
L3+
DI/DO 18
1)
DI/DO 20
7
8
9
10
DI/DO 21
DI/DO 23
DI/DO 22
M3
M
M
M
1) Can be parameterized individually as input or output.
G_D211_EN_00040
ext.
24 V
DRIVE-CLiQ socket
DRIVE-CLiQ socket
© Siemens AG 2017