SINAMICS S120 drive system
Chassis format
Liquid-cooled Active Interface Modules in chassis format
7
■
Technical specifications
Line voltage 380 ... 480 V 3 AC
Active Interface Module
6SL3305-7TE41-4AA3
Suitable for Active Line Module
• Rated power at 400 V
kW
900/630
- Liquid-cooled
6SL3335-7TE41-4AA3
6SL3335-7TE41-0AA3
Rated current
A
1405
Bypass contactor
1)
3WL1116-2BB34-4AN2-Z
Z = C22
2)
Current demand
• 24 V DC auxiliary power supply
A
0.17
• 230 V 2 AC
-
Inrush current
A
1.0
-
Holding current
A
0.1
DC link capacitance
of the drive line-up, max.
3)
μ
F
230400
Coolant volume flow
l/min
16
Pressure drop, typ.
for volume flow
Pa
70000
Sound pressure level
L
pA
(1 m) at 50/60 Hz
dB
71/71
Frame size
JIL
Filter reactor
Power loss
4)
• At 50 Hz 400 V
kW
8.6
• At 60 Hz 460 V
kW
8.6
• Dissipated to ambient air
kW
0.9
Liquid volume
• Of integrated reactor cooler
dm
3
0.6
• Of hoses supplied
dm
3
/m
0.285
Coolant volume flow
l/min
8
Pressure drop, typ.
for volume flow
Pa
70000
Heat exchanger material
Aluminum
Line/load connection
L1, L2, L3 / U2, V2, W2
Flat connector for M12 screws
PE/GND connection
M10 stud
• Conductor cross section, max. (IEC)
mm
2
1 × 240
Degree of protection
IP00
Dimensions
• Width
mm (in)
373 (14.7)
• Height
mm (in)
716 (28.2)
• Depth
mm (in)
575 (22.6)
Weight, approx.
kg (lb)
299 (659)
Filter module
Power loss
4)
• At 50 Hz 400 V
kW
3.6
• At 60 Hz 460 V
kW
3.6
• Dissipated to ambient air
kW
0.15
Liquid volume
dm
3
1
Heat exchanger material
Aluminum
PE/GND connection
Flat connector for M8 screw
• Conductor cross section, max. (IEC)
mm
2
2 × 120
Degree of protection
IP00
Dimensions
• Width
mm (in)
511 (20.1)
• Height
mm (in)
840 (33.1)
• Depth
mm (in)
574 (22.6)
Weight, approx.
kg (lb)
110 (243)
1)
The bypass contactor is not included in the scope of supply.
2)
The breakers must always be switched ON and OFF by the sequence
control. An interlocking set 3WL9111-0BA21-0AA0 as described in
Catalog LV 10 should be provided for the bypass contactor to exclude
the risk of unintentional manual operation. Manual operation bypasses the
pre-charging circuit and can therefore destroy the Active Line Module.
3)
Information on higher capacities is included in the SINAMICS Low Voltage
Engineering Manual.
4)
The specified power loss represents the maximum value at 100 % utilization.
The value is lower under normal operating conditions. To ensure safe dissi-
pation of the minor power loss released to the ambient air, it is important to
follow the instructions pertaining to control cabinet installation in the
SINAMICS Low Voltage Engineering Manual.
© Siemens AG 2017