SIEMENS
7/177
Siemens D 21.4 · 2017
SINAMICS S120 drive system
Chassis format
Liquid-cooled Active Line Modules in chassis format
7
■
Technical specifications
(continued)
Line voltage 380 V... 480 V 3 AC
Active Line Modules
6SL3335-
7TE35-0AA3
6SL3335-
7TE36-1AA3
6SL3335-
7TE38-4AA3
6SL3335-
7TE41-0AA3
6SL3335-
7TE41-4AA3
Rated power
• At
I
rated DC
(50 Hz 400 V)
kW
300
380
500
630
900
• At
I
H DC
(50 Hz 400 V)
kW
270
335
465
545
780
• At
I
rated DC
(60 Hz 460 V)
hp
500
600
700
900
1250
• At
I
H DC
(60 Hz 460 V)
hp
400
500
700
800
1000
DC link current
• Rated current
I
rated DC
A
549
677
941
1100
1573
• Base-load current
I
H DC
1)
A
489
603
837
982
1401
• Maximum current
I
max DC
A
823
1017
1410
1654
2361
Infeed/regenerative feedback current
• Rated current
I
rated I
A
490
605
840
985
1405
• Maximum current
I
max I
A
735
907
1260
1477
2055
Current demand
• 24 V DC auxiliary power supply
A
1.5
1.6
1.6
1.6
1.6
DC link capacitance
• Active Line Module
μ
F
9600
12600
17400
18900
28800
Pulse frequency
kHz
4
2.5
2.5
2.5
2.5
Power loss, at 50 Hz 400 V
2)
• Dissipated to coolant
kW
3.42
4.65
5.52
7.46
9.58
• Dissipated to ambient air
kW
0.14
0.17
0.23
0.44
0.62
• Total
kW
3.56
4.82
5.75
7.9
10.2
Coolant volume flow
3)
l/min
12
16
16
27
27
Liquid volume
of the integrated heat exchanger
dm
3
0.91
0.74
0.74
1.56
1.56
Pressure drop, typ.
4)
for volume flow
Pa
70000
70000
70000
70000
70000
Heat exchanger material
Stainless steel
Aluminum
Aluminum
Aluminum
Aluminum
Sound pressure level
L
pA
5)
(1 m) at 50/60 Hz
dB
69/73
70/73
70/73
71/73
71/73
Line connection
U1, V1, W1
Hole for M12
2 x hole for M12
2 x hole for M12
2 x hole for M12
2 x hole for M12
• Conductor cross section, max. (IEC)
mm
2
2 × 240
4 × 185
4 × 185
Busbar
Busbar
DC link connection
DCP, DCN
2 × hole for M12
Busbar
2 × hole for M12
Busbar
2 × hole for M12
Busbar
2 × hole for M12
Busbar
2 × hole for M12
Busbar
PE/GND connection
2 × hole for M12
2 × hole for M12
2 × hole for M12
2 × hole for M12
2 × hole for M12
• Conductor cross section, max. (IEC)
mm
2
2 × 240
4 × 185
4 × 185
4 × 240
4 × 240
Cable length, max.
6)
• Shielded
m (ft)
2700 (8859)
3900 (12796)
3900 (12796)
3900 (12796)
3900 (12796)
• Unshielded
m (ft)
4050 (13288)
5850 (1168)
5850 (1168)
5850 (1168)
5850 (1168)
Dimensions
• Width
mm (in)
150 (5.91)
265 (10.4)
265 (10.4)
295 (11.6)
295 (11.6)
• Height
mm (in)
1172 (46.1)
1002 (39.4)
1002 (39.4)
1516 (59.7)
1516 (59.7)
• Depth
mm (in)
545 (21.5)
545 (21.5)
545 (21.5)
545 (21.5)
545 (21.5)
Weight, approx.
kg (lb)
80 (176)
110 (243)
110 (243)
220 (486)
220 (486)
Frame size
GXL
HXL
HXL
JXL
JXL
Minimum short-circuit current
7)
A
8000
9200
10400
16000
21000
1)
The base-load current
I
H DC
is the basis for a duty cycle of 150 % for 60 s
or
I
max DC
for 5 s with a duty cycle duration of 300 s.
2)
The specified power loss represents the maximum value at 100 % utilization.
The value is lower under normal operating conditions. To ensure safe dissi-
pation of the minor power loss released to the ambient air, it is important to
follow the instructions pertaining to control cabinet installation in the
SINAMICS Low Voltage Engineering Manual.
3)
The value applies to coolants comprising water and a mixture of water and
anti-freeze agent.
4)
The value is valid for water as coolant.
Additional information and notes on
other coolants is provided in the SINAMICS Low Voltage Engineering
Manual
.
5)
Total sound pressure level of Active Interface Module and Active Line
Module.
6)
Total of all motor cables and DC link. Longer cable lengths for specific
configurations are available on request.
For additional information, please
refer to the SINAMICS Low Voltage Engineering Manual
.
7)
Current required for reliably triggering protective devices.
© Siemens AG 2017