SIEMENS
7/175
Siemens D 21.4 · 2017
SINAMICS S120 drive system
Chassis format
Liquid-cooled Active Line Modules in chassis format
7
■
Overview
The self-commutated infeed/regenerative feedback units (with
IGBTs in infeed and regenerative feedback directions) generate
a regulated DC link voltage. This means that the connected
Motor Modules are decoupled from the line voltage. Line voltage
fluctuations within the permissible supply tolerances have no
effect on the motor voltage.
If required, the Active Line Modules can also provide reactive
power compensation.
Active Line Modules are designed for connection to grounded
TN/TT and non-grounded IT supply systems.
Liquid-cooled Active Line Modules are especially suitable for
applications where installation space is restricted and environ-
mental conditions are harsh. Liquid cooling ensures efficient
heat dissipation.
Active Line Modules are always operated together with the as-
sociated Active Interface Modules. These include the necessary
pre-charging circuit as well as a Clean Power Filter.
■
Design
The liquid-cooled Active Line Modules have the following
interfaces as standard:
•
1 line supply connection
•
1 connection for the 24 V DC electronics power supply
•
1 DC link connection (DCP, DCN) for supplying the connected
Motor Modules
•
3 DRIVE-CLiQ sockets
•
1 temperature sensor input for KTY84-130, Pt1000, PTC or Pt100
(Pt1000 can be used from firmware V4.7 HF17)
•
1 PE connection
•
2 coolant connections
The status of the Active Line Modules is indicated via three LEDs.
The following are included in the scope of supply of the
Active Line Modules:
•
1 DRIVE-CLiQ cable for connection to the Control Unit
•
2 seals for coolant connections
•
1 set of warning labels in 30 languages
(BG, CN, CZ, DE, DK, EE, ES, FI, FR, GB, GR, HU, IE, IS, IT,
JP, KR, LT, LV, MT, NL, NO, PL, PT, RO, RU, SE, SI, SK, TR)
■
Selection and ordering data
Rated power
at 400 V, 50 Hz
(460 V, 60 Hz) or
690 V, 50 Hz
(575 V, 60 Hz)
Rated infeed/
regenerative
feedback current
Active Line Module
kW (hp)
A
Article No.
Line voltage 380 ... 480 V 3 AC
300 (500)
490
6SL3335-7TE35-0AA3
380 (600)
605
6SL3335-7TE36-1AA3
500 (700)
840
6SL3335-7TE38-4AA3
630 (900)
985
6SL3335-7TE41-0AA3
900 (1250)
1405
6SL3335-7TE41-4AA3
Line voltage 500 ... 690 V 3 AC
630 (675)
575
6SL3335-7TG35-8AA3
800 (900)
735
6SL3335-7TG37-4AA3
900 (975)
810
6SL3335-7TG38-1AA3
1100 (1250)
1020
6SL3335-7TG41-0AA3
1400 (1500)
1270
6SL3335-7TG41-3AA3
1700 (1880)
1560
6SL3335-7TG41-6AA3
Description
Article No.
Accessories
3-way valve
1)
VXF41.../VXG41...
Actuator for 3-way valve
1)
• 230 V 1 AC
SAX31...
• 24 V AC/DC
SAX61.../SAX81...
Accessories
Dust protection blanking plugs
(50 units)
For DRIVE-CLiQ port
6SL3066-4CA00-0AA0
1)
Recommended components for installing a flow control as condensation
protection; manufactured by Siemens Building Technologies.
© Siemens AG 2017