SIEMENS
7/156
Siemens D 21.4 · 2017
SINAMICS S120 drive system
Chassis format
Air-cooled Motor Modules in chassis format
7
■
Technical specifications
(continued)
Line voltage 500 ... 690 V 3 AC
DC link voltage 675 ... 1035 V DC
Motor Modules
6SL3320-1TG31-8AA3
6SL3320-1TG32-2AA3
6SL3320-1TG32-6AA3
6SL3320-1TG33-3AA3
Type rating
• At
I
L
(50 Hz 690 V)
1)
kW
160
200
250
315
• At
I
H
(50 Hz 690 V)
1)
kW
132
160
200
250
• At
I
L
(50 Hz 500 V)
1)
kW
110
132
160
200
• At
I
H
(50 Hz 500 V)
1)
kW
90
110
132
160
• At
I
L
(60 Hz 575 V)
2)
hp
150
200
250
300
• At
I
H
(60 Hz 575 V)
2)
hp
150
200
200
250
Output current
• Rated current
I
rated O
A
175
215
260
330
• Base-load current
I
L
3)
A
171
208
250
320
• Base-load current
I
H
4)
A
157
192
233
280
• Maximum current
I
max A
A
255
312
375
480
DC link current
• Rated current
I
rated DC
when supplied via
-
Basic/Smart Line Module
A
210
258
312
396
-
Active Line Module
A
189
232
281
356
• Base-load current
I
L DC
3)
when supplied via
-
Basic/Smart Line Module
A
204
251
304
386
-
Active Line Module
A
184
226
273
347
• Base-load current
I
H DC
4)
when supplied via
-
Basic/Smart Line Module
A
186
229
277
352
-
Active Line Module
A
168
206
250
316
Current demand
• 24 V DC auxiliary power supply
A
0.9
0.9
0.9
0.9
• 500 V AC
A
1.5
1.5
1.5
1.5
• 690 V AC
A
1.0
1.0
1.0
1.0
DC link capacitance
μ
F
2800
2800
3900
4200
Pulse frequency
5)
• Rated frequency
kHz
1.25
1.25
1.25
1.25
• Pulse frequency, max.
-
Without current derating
kHz
1.25
1.25
1.25
1.25
-
With current derating
kHz
7.5
7.5
7.5
7.5
Power loss, max.
6)
• At 50 Hz 690 V
kW
2.67
3.09
3.62
4.34
• At 60 Hz 575 V
kW
2.5
2.91
3.38
3.98
Cooling air requirement
m
3
/s (ft
3
/s)
0.36 (12.7)
0.36 (12.7)
0.36 (12.7)
0.36 (12.7)
Sound pressure level
L
pA
(1 m) at 50/60 Hz
dB
69/73
69/73
69/73
69/73
DC link connection
DCP, DCN
M10 screw
M10 screw
M10 screw
M10 screw
• Conductor cross section, max. (IEC)
mm
2
2 × 240
2 × 240
2 × 240
2 × 240
Connection for Braking Module
DCPA, DCNA
7)
M6 stud
M6 stud
M6 stud
M6 stud
Connection for dv/dt filter
DCPS, DCNS
M8 screw
M8 screw
M8 screw
M8 screw
• Conductor cross section, max. (IEC)
mm
2
1 × 70
1 × 70
1 × 70
1 × 70
Motor connection
U2, V2, W2
M10 screw
M10 screw
M10 screw
M10 screw
• Conductor cross section, max. (IEC)
mm
2
2 × 240
2 × 240
2 × 240
2 × 240
Footnotes see next page.