SIEMENS
7/152
Siemens D 21.4 · 2017
SINAMICS S120 drive system
Chassis format
Air-cooled Motor Modules in chassis format
7
■
Technical specifications
(continued)
Line voltage 380 ... 480 V 3 AC
DC link voltage 510 ... 720 V DC
Motor Modules
6SL3320-1TE41-0AA3
6SL3320-1TE41-2AA3
6SL3320-1TE41-4AA3
Type rating
• At
I
L
(50 Hz 400 V)
1)
kW
560
710
800
• At
I
H
(50 Hz 400 V)
1)
kW
450
560
710
• At
I
L
(60 Hz 460 V)
2)
hp
800
1000
1150
• At
I
H
(60 Hz 460 V)
2)
hp
700
900
1000
Output current
• Rated current
I
rated O
A
985
1260
1405
• Base-load current
I
L
3)
A
960
1230
1370
• Base-load current
I
H
4)
A
860
1127
1257
• Maximum current
I
max A
A
1440
1845
2055
DC link current
• Rated current
I
rated DC
when supplied via
-
Basic/Smart Line Module
A
1182
1512
1686
-
Active Line Module
A
1064
1361
1517
• Base-load current
I
L DC
3)
when supplied via
-
Basic/Smart Line Module
A
1152
1474
1643
-
Active Line Module
A
1037
1326
1479
• Base-load current
I
H DC
4)
when supplied from
-
Basic/Smart Line Module
A
1051
1345
1500
-
Active Line Module
A
946
1211
1350
Current demand
• 24 V DC auxiliary power supply
A
1.25
1.4
1.4
• 400 V AC
A
5.4
5.4
5.4
DC link capacitance
μ
F
18900
26100
28800
Pulse frequency
5)
• Rated pulse frequency
kHz
1.25
1.25
1.25
• Pulse frequency, max.
-
Without current derating
kHz
1.25
1.25
1.25
-
With current derating
kHz
7.5
7.5
7.5
Power loss, max.
6)
• At 50 Hz 400 V
kW
9.5
11.1
12.0
• At 60 Hz 460 V
kW
10.2
12.0
13.0
Cooling air requirement
m
3
/s (ft
3
/s)
1.08 (38.1)
1.08 (38.1)
1.08 (38.1)
Sound pressure level
L
pA
(1 m) at 50/60 Hz
dB
71/73
71/73
71/73
DC link connection
DCP, DCN
4 × hole for M10
Busbar
4 × hole for M10
Busbar
4 × hole for M10
Busbar
Connection for Braking Module
DCPA, DCNA
7)
Connection for connection clip
Connection for connection clip
Connection for connection clip
Connection for dv/dt filter
DCPS, DCNS
2 x M10 screw
2 x M10 screw
2 x M10 screw
• Conductor cross section, max. (IEC)
mm
2
2 × 185
2 × 185
2 × 185
Motor connection
U2, V2, W2
3 × M12 screw
3 × M12 screw
3 × M12 screw
• Conductor cross section, max. (IEC)
mm
2
6 × 240
6 × 240
6 × 240
Cable length, max.
8)
• Shielded
m (ft)
300 (984)
300 (984)
300 (984)
• Unshielded
m (ft)
450 (1476)
450 (1476)
450 (1476)
Footnotes see next page.
© Siemens AG 2017