SIEMENS
7/150
Siemens D 21.4 · 2017
SINAMICS S120 drive system
Chassis format
Air-cooled Motor Modules in chassis format
7
■
Technical specifications
(continued)
Line voltage 380 ... 480 V 3 AC
DC link voltage 510 ... 720 V DC
Motor Modules
6SL3320-1TE36-1AA3
6SL3320-1TE37-5AA3
6SL3320-1TE38-4AA3
Type rating
• At
I
L
(50 Hz 400 V)
1)
kW
315
400
450
• At
I
H
(50 Hz 400 V)
1)
kW
250
315
400
• At
I
L
(60 Hz 460 V)
2)
hp
500
600
700
• At
I
H
(60 Hz 460 V)
2)
hp
350
450
600
Output current
• Rated current
I
rated O
A
605
745
840
• Base-load current
I
L
3)
A
590
725
820
• Base-load current
I
H
4)
A
460
570
700
• Maximum current
I
max A
A
885
1087
1230
DC link current
• Rated current
I
rated DC
when supplied via
-
Basic/Smart Line Module
A
726
894
1008
-
Active Line Module
A
653
805
907
• Base-load current
I
L DC
3)
when supplied via
-
Basic/Smart Line Module
A
707
871
982
-
Active Line Module
A
636
784
884
• Base-load current
I
H DC
4)
when supplied via
-
Basic/Smart Line Module
A
646
795
897
-
Active Line Module
A
581
716
807
Current demand
• 24 V DC auxiliary power supply
A
1.0
1.0
1.0
• 400 V AC
A
3.6
3.6
3.6
DC link capacitance
μ
F
12600
15600
16800
Pulse frequency
5)
• Rated frequency
kHz
1.25
1.25
1.25
• Pulse frequency, max.
-
Without current derating
kHz
1.25
1.25
1.25
-
With current derating
kHz
7.5
7.5
7.5
Power loss, max.
6)
• At 50 Hz 400 V
kW
5.84
6.68
7.15
• At 60 Hz 460 V
kW
6.3
7.3
7.8
Cooling air requirement
m
3
/s (ft
3
/s)
0.78 (27.5)
0.78 (27.5)
0.78 (27.5)
Sound pressure level
L
pA
(1 m) at 50/60 Hz
dB
70/73
70/73
70/73
DC link connection
DCP, DCN
4 × hole for M10
Busbar
4 × hole for M10
Busbar
4 × hole for M10
Busbar
Connection for Braking Module
DCPA, DCNA
7)
Connection for connection clip
Connection for connection clip
Connection for connection clip
Connection for dv/dt filter
DCPS, DCNS
M10 screw
M10 screw
M10 screw
• Conductor cross section, max. (IEC)
mm
2
1 × 185
1 × 185
1 × 185
Motor connection
U2, V2, W2
2 × M12 screw
2 × M12 screw
2 × M12 screw
• Conductor cross section, max. (IEC)
mm
2
4 × 240
4 × 240
4 × 240
Cable length, max.
8)
• Shielded
m (ft)
300 (984)
300 (984)
300 (984)
• Unshielded
m (ft)
450 (1476)
450 (1476)
450 (1476)
Footnotes see next page.
© Siemens AG 2017