SIEMENS
7/123
Siemens D 21.4 · 2017
SINAMICS S120 drive system
Chassis format
Air-cooled Power Modules in chassis format
7
■
Technical specifications
(continued)
Line voltage 380 ... 480 V 3 AC
Power Modules
6SL3310-
1TE32-1AA3
6SL3310-
1TE32-6AA3
6SL3310-
1TE33-1AA3
6SL3310-
1TE33-8AA3
6SL3310-
1TE35-0AA3
Type rating
• At
I
L
(50 Hz 400 V)
1)
kW
110
132
160
200
250
• At
I
H
(50 Hz 400 V)
1)
kW
90
110
132
160
200
• At
I
L
(60 Hz 460 V)
2)
hp
150
200
250
300
400
• At
I
H
(60 Hz 460 V)
2)
hp
150
200
200
250
350
Output current
• Rated current
I
rated O
A
210
260
310
380
490
• Base-load current
I
L
3)
A
205
250
302
370
477
• Base-load current
I
H
4)
A
178
233
277
340
438
• Maximum current
I
max O
A
307
375
453
555
715
Input current
• Rated input current
I
rated I
A
229
284
338
395
509
• Maximum input current
I
max I
A
335
410
495
606
781
Current demand
• 24 V DC auxiliary power supply
A
0.8
0.8
0.9
0.9
0.9
Pulse frequency
5)
• Rated frequency
kHz
2
2
2
2
2
• Pulse frequency, max.
-
Without current derating
kHz
2
2
2
2
2
-
With current derating
kHz
8
8
8
8
8
Power loss, max.
6)
• At 50 Hz 400 V
kW
2.46
3.27
4
4.54
5.78
• At 60 Hz 460 V
kW
2.54
3.36
4.07
4.67
5.96
Cooling air requirement
m
3
/s (ft
3
/s)
0.17 (6.0)
0.23 (8.1)
0.36 (12.7)
0.36 (12.7)
0.36 (12.7)
Sound pressure level
L
pA
(1 m) at 50/60 Hz
dB
66/67
71/71
68/72
68/72
68/72
Line connection
U1, V1, W1
Flat connector for
M10 screw
Flat connector for
M10 screw
Flat connector for
M10 screw
Flat connector for
M10 screw
Flat connector for
M10 screw
• Conductor cross section, max. (IEC)
mm
2
2 × 185
2 × 185
2 × 240
2 × 240
2 × 240
Motor connection
U2/T1, V2/T2, W2/T3
Flat connector for
M10 screw
Flat connector for
M10 screw
Flat connector for
M10 screw
Flat connector for
M10 screw
Flat connector for
M10 screw
• Conductor cross section, max. (IEC)
mm
2
2 × 185
2 × 185
2 × 240
2 × 240
2 × 240
Cable length, max.
7)
• Shielded
m (ft)
300 (984)
300 (984)
300 (984)
300 (984)
300 (984)
• Unshielded
m (ft)
450 (1476)
450 (1476)
450 (1476)
450 (1476)
450 (1476)
PE1/GND connection
Flat connector for
M10 screw
Flat connector for
M10 screw
Flat connector for
M10 screw
Flat connector for
M10 screw
Flat connector for
M10 screw
• Conductor cross section, max. (IEC)
mm
2
2 × 185
2 × 185
2 × 240
2 × 240
2 × 240
PE2/GND connection
M10 screw
M10 screw
M10 screw
M10 screw
M10 screw
• Conductor cross section, max. (IEC)
mm
2
2 × 185
2 × 185
2 × 240
2 × 240
2 × 240
Degree of protection
IP20
IP20
IP20
IP20
IP20
Dimensions
• Width
mm (in)
326 (12.8)
326 (12.8)
326 (12.8)
326 (12.8)
326 (12.8)
• Height
mm (in)
1400 (55.1)
1400 (55.1)
1533 (60.3)
1533 (60.3)
1533 (60.3)
• Depth
mm (in)
356 (14.0)
8)
356 (14.0)
8)
549 (21.6)
549 (21.6)
549 (21.6)
Weight, approx.
kg (lb)
104 (229)
104 (229)
162 (357)
162 (357)
162 (357)
Frame size
FX
FX
GX
GX
GX
Minimum short-circuit current
9)
A
3000
3600
4400
4400
8000
1)
Rated output of a typical 6-pole standard induction motor based on
I
L
or
I
H
for 400 V 3 AC 50 Hz.
2)
Rated output of a typical 6-pole standard induction motor based on
I
L
or
I
H
for 460 V 3 AC 60 Hz.
3)
The base-load current
I
L
is based on a duty cycle of 110 % for 60 s or
150 % for 10 s with a duty cycle duration of 300 s.
4)
The base-load current
I
H
is based on a duty cycle of 150 % for 60 s or
160 % for 10 s with a duty cycle duration of 300 s.
5)
Information regarding the correlation between the pulse frequency and
maximum output current/output frequency is provided in the
SINAMICS Low Voltage Engineering Manual.
6)
The specified power loss represents the maximum value at 100 % utilization.
The value is lower under normal operating conditions.
7)
Longer cable lengths for specific configurations are available on request.
For additional information, please refer to the SINAMICS Low Voltage
Engineering Manual.
8)
Depth = 421 mm (16.6 in) including front cover when CU310-2 Control Unit
is installed.
9)
Current required for reliably triggering protective devices.
© Siemens AG 2017