SIEMENS
7/109
Siemens D 21.4 · 2017
SINAMICS S120 drive system
Booksize format
SINAMICS S120M distributed servo drive
7
■
Technical specifications
1)
Only applies for an electronics input voltage > 26.5 V.
AM600 Adapter Module
6SL3555-2BC10-0AA0
Line connection voltage
380 ... 480 V 3 AC ±10 %
(in operation -15 % <1 min)
Line frequency
47 ... 63 Hz
Electronics power supply (input)
• Electronics voltage
24 V DC -15 ... +20 %
• Electronics current
20 A
• 24 V busbar current-carrying capacity
20 A
Electronics line supply (output)
• Electronics power supply
48 V DC
• Rated power
P
out
1)
0.45 kW
• Output current
10 A
DC-link supply
• DC-link voltage
510 ... 720 V DC
• Output current
I
rated
25 A
• Base-load current
I
base
21.3 A
• S6 current
I
S6
40 %
30 A
• Peak current
I
max
50 A
• DC-link capacitance
705
μ
F ±20 %
• DC-link busbar current-carrying
capacity
100 A
Rated power, electrical
For a DC-link voltage of 600 V DC
14.7 kW
Total power loss
Including electronics losses
0.06 kW
Minimum cable length to the 1st axis
3 m (9.84 ft)
Format
Booksize compact
Degree of protection
IP20
Ambient temperature during
operation, perm.
0 ... 40 °C (32 ... 104 °F)
>40 ... 55 °C (104 ... 131 °F)
see derating characteristics of the
Line Modules
Dimensions
• Width
75 mm (2.95 in)
• Height
270 mm (10.63 in)
• Depth
224 mm (8.82 in)
Weight, approx.
3.2 kg (7 lb)
AM600 Adapter Module
6SL3555-2BC10-0AA0
Distributed drive unit
(synchronous servomotor
with Motor Module and encoder)
6SL3532-
6DF71-0R..
6SL3540-
6DF71-0R..
6SL3542-
6DF71-0R..
6SL3562-
6DF71-0R..
6SL3563-
6DF71-0R..
Type of construction
IM B5
IM V1
IM V3
IM B5
IM V1
IM V3
IM B5
IM V1
IM V3
IM B5
IM V1
IM V3
IM B5
IM V1
IM V3
Cooling method
Surface convection
Surface convection
Surface convection
Surface convection
Surface convection
Ambient temperature during
operation, perm.
°C (°F)
-15 ... +40
(5 ... 104)
>40 ... 55
(104 ... 131)
with derating
-15 ... +40
(5 ... 104)
>40 ... 55
(104 ... 131)
with derating
-15 ... +40
(5 ... 104)
>40 ... 55
(104 ... 131)
with derating
-15 ... +40
(5 ... 104)
>40 ... 55
(104 ... 131)
with derating
-15 ... +40
(5 ... 104)
>40 ... 55
(104 ... 131)
with derating
Installation altitude, max.
m (ft)
1000 (3281)
1000 (3281)
1000 (3281)
1000 (3281)
1000 (3281)
Sound pressure level
L
pA
(1 m) acc. to DIN EN ISO 1680,
max.
Tolerance +3 dB
dB
55
55
55
65
65
Vibrational load in operation
Acc. to IEC 68-2-6, DIN EN 60721
Part 3-0 and Part 3-3
Class 3M3
Class 3M3
Class 3M3
Class 3M3
Class 3M3
• Constant deflection in frequency
range 2 … 9 Hz
mm (in)
1.5 (0.06)
1.5 (0.06)
1.5 (0.06)
1.5 (0.06)
1.5 (0.06)
• Constant deflection in frequency
range 10 … 200 Hz
0.5 ×
g
0.5 ×
g
0.5 ×
g
0.5 ×
g
0.5 ×
g
Shock load in operation
Acc. to DIN EN 60721 Part 3-0 and
Part 3-3
Class 3M3
Class 3M3
Class 3M3
Class 3M3
Class 3M3
• Max. peak acceleration
7 ×
g
7 ×
g
7 ×
g
7 ×
g
7 ×
g
• Shock duration
ms
22
22
22
22
22
Degree of protection
• Standard
IP54
(IP65 available soon)
IP65
IP65
IP65
IP65
• Optional
IP67
IP67
IP67
IP67
IP67
Weight, approx.
• Without brake
kg (lb)
4.1 (9.04)
5.3 (11.6)
7.1 (15.6)
11.9 (26.2)
13.9 (30.6)
• With brake
kg (lb)
4.5 (9.92)
6 (13.2)
7.8 (17.2)
13.3 (29.3)
15.3 (33.7)
© Siemens AG 2017