SIEMENS
7/76
Siemens D 21.4 · 2017
SINAMICS S120 drive system
Booksize format
Single Motor Modules in booksize format
7
■
Integration
(continued)
Connection example of Single Motor Modules in booksize format, 45 A to 200 A
X201
X200
+Temp
X21
EP M1
EP +24 V
BR+
BR-
X202
4
3
2
1
M
3 ~
E
U2
V2
X11
M
+
DCN
DCP
M
+
DCN
DCP
Single Motor Module
5)
1)
+
X12
-
2
1
1
2
W2
READY
LEDs
DC LINK
2)
3)
M
-Temp
4)
1) Required for Safety.
5)
Fan insert for 132 A and 200 A Single Motor Modules
.
The fan insert is supplied with the Single Motor Module.
3) The braking signal has an integrated overvoltage protection.
An external circuit of the holding brake is not necessary.
4) Contacting via shield plate.
2)
Temperature sensor terminal for motors without DRIVE-CLiQ interface.
Fan
DRIVE-CLiQ socket 1
DRIVE-CLiQ socket 0
DRIVE-CLiQ socket 2
24 V DC busbars
DC link busbars
G_D212_EN_00033g
© Siemens AG 2017