SIEMENS
7/74
Siemens D 21.4 · 2017
SINAMICS S120 drive system
Booksize format
Single Motor Modules in booksize format
7
■
Technical specifications
(continued)
DC link voltage 510 ... 720 V DC
Single Motor Module in booksize format
Internal air cooling
6SL3120-...
1TE24-5AA3
1TE26-0AA3
1TE28-5AA3
1TE31-3AA3
1TE32-0AA4
Output current
• Rated current
I
rated
A
45
60
85
132
200
• Base-load current
I
H
A
38
52
68
105
141
• For S6 duty (40 %)
I
S6
A
60
80
110
150
230
•
I
max
A
85
113
141
210
282
Type rating
1)
• Based on
I
rated
kW (hp)
24 (30)
32 (40)
46 (60)
71 (100)
107 (150)
• Based on
I
H
kW (hp)
21 (25)
28 (40)
37 (50)
57 (75)
76 (100)
Rated pulse frequency
kHz
4
4
4
4
4
DC link current
I
d
2)
A
54
72
102
158
200
Current carrying capacity
• DC link busbars
A
200
200
200
200
200
• 24 V DC busbars
3)
A
20
20
20
20
20
DC link capacitance
μ
F
1175
1410
1880
2820
3995
Current requirement
At 24 V DC, max.
A
1.2
1.2
1.5
1.5
1.5
Power loss
4)
typ.
5)
/ max.
kW
0.38/0.46
0.55/0.62
0.77/0.79
1.26/1.29
2.03/2.09
Cooling air requirement
m
3
/s (ft
3
/s)
0.031 (1.1)
0.031 (1.1)
0.044 (1.6)
0.144 (5.1)
0.144 (5.1)
Sound pressure level
L
pA
(1 m)
dB
<65
<65
<60
<73
<73
Motor connection
U2, V2, W2
M6 screw studs
(X1)
M6 screw studs
(X1)
M8 Screw studs
(X1)
M8 Screw studs
(X1)
M8 Screw studs
(X1)
• Conductor cross-section, max.
mm
2
2.5 ... 50
2.5 ... 50
2.5 ... 95, 2 × 35
2.5 ... 120, 2 × 50
2.5 ... 120, 2 × 50
Shield connection
See Accessories
See Accessories
See Accessories
See Accessories
See Accessories
PE connection
M6 screw
M6 screw
M6 screw
M8 screw
M8 screw
Motor brake connection
Plug-in connector
(X11), 24 V DC, 2 A
Plug-in connector
(X11), 24 V DC, 2 A
Plug-in connector
(X11), 24 V DC, 2 A
Plug-in connector
(X11), 24 V DC, 2 A
Plug-in connector
(X11), 24 V DC, 2 A
Motor cable length, max.
• Shielded
m (ft)
100 (328)
100 (328)
100 (328)
100 (328)
100 (328)
• Unshielded
m (ft)
150 (492)
150 (492)
150 (492)
150 (492)
150 (492)
Degree of protection
IP20
IP20
IP20
IP20
IP20
Dimensions
• Width
mm (in)
150 (5.91)
150 (5.91)
200 (7.87)
300 (11.8)
300 (11.8)
• Height
mm (in)
380 (14.96)
380 (14.96)
380 (14.96)
380 (14.96)
380 (14.96)
-
With fan
6)
mm (in)
–
–
–
629 (24.8)
629 (24.8)
• Depth
mm (in)
270 (10.6)
270 (10.6)
270 (10.6)
270 (10.6)
270 (10.6)
Weight, approx.
kg (lb)
9 (19.9)
9 (19.9)
15 (33.1)
21 (46.3)
21 (46.3)
1)
Rated power of a typical standard asynchronous (induction) motor at
600 V DC link voltage.
2)
Rated DC link current for dimensioning an external DC connection.
3)
If, due to a number of Line Modules and Motor Modules being mounted
side-by-side, the current carrying capacity exceeds 20 A, an additional
24 V DC connection using a 24 V terminal adapter is required (max.
cross-section 6 mm
2
, max. fuse protection 20 A).
4)
Power loss of Motor Module at rated power including losses of 24 V DC
electronics power supply.
5)
At max. motor cable length 30 m (98.43 ft), pulse frequency 4 kHz and
DC link voltage 540 ... 600 V.
6)
The fan is supplied with the Motor Module and must be installed before the
Motor Module is commissioned.
© Siemens AG 2017