SIEMENS
7/73
Siemens D 21.4 · 2017
SINAMICS S120 drive system
Booksize format
Single Motor Modules in booksize format
7
■
Technical specifications
(continued)
DC link voltage 510 ... 720 V DC
Single Motor Module in booksize format
Internal air cooling C type
6SL3120-...
–
–
–
1TE21-8AC0
1TE23-0AC0
Internal air cooling D type
6SL3120-...
1TE13-0AD0
1TE15-0AD0
1TE21-0AD0
1TE21-8AD0
1TE23-0AD0
Output current
• Rated current
I
rated
A
3
5
9
18
30
• Base-load current
I
H
A
2.6
4.3
7.7
15.3
25.5
• For S6 duty (40 %)
I
S6
-
C type
A
–
–
–
24
40
-
D type
A
4
6.7
12
24
40
•
I
max
-
C type
A
–
–
–
36
56
-
D type
A
9
15
27
54
90
Type rating
1)
• Based on
I
rated
kW (hp)
1.6 (1.5)
2.7 (3)
4.8 (5)
9.7 (10)
16 (20)
• Based on
I
H
kW (hp)
1.4 (1)
2.3 (2.5)
4.1 (5)
8.2 (10)
13.7 (18)
Rated pulse frequency
kHz
4
4
4
4
4
DC link current
I
d
2)
A
3.6
6
11
22
36
Current carrying capacity
• DC link busbars
A
100
3)
100
3)
100
3)
100
3)
100
3)
• 24 V DC busbars
4)
A
20
20
20
20
20
DC link capacitance
μ
F
110
110
110
220
705
Current requirement
At 24 V DC, max.
A
0.75
0.75
0.75
0.75
0.8
Power loss
5)
typ.
6)
/ max.
kW
0.03/0.05
0.04/0.07
0.06/0.1
0.14/0.19
0.26/0.31
Cooling air requirement
m
3
/s (ft
3
/s)
0.009 (0.3)
0.009 (0.3)
0.009 (0.3)
0.009 (0.3)
0.0155 (0.5)
Sound pressure level
L
pA
(1 m)
dB
<60
<60
<60
<60
<60
Motor connection
U2, V2, W2
Plug connector
(X1)
7)
,
1.5 ... 6 mm
2
Plug connector
(X1)
7)
,
1.5 ... 6 mm
2
Plug connector
(X1)
7)
,
1.5 ... 6 mm
2
Plug connector
(X1)
7)
,
1.5 ... 6 mm
2
Plug connector
(X1)
7)
,
1.5 ... 6 mm
2
PE connection
M5 screw
M5 screw
M5 screw
M5 screw
M5 screw
Motor brake connection
Integrated into the
plug-in motor
connector (X1),
24 V DC, 2 A
Integrated into the
plug-in motor
connector (X1),
24 V DC, 2 A
Integrated into the
plug-in motor
connector (X1),
24 V DC, 2 A
Integrated into the
plug-in motor
connector (X1),
24 V DC, 2 A
Integrated into the
plug-in motor
connector (X1),
24 V DC, 2 A
Motor cable length, max.
• Shielded
m (ft)
50 (164)
50 (164)
50 (164)
70 (230)
100 (328)
• Unshielded
m (ft)
75 (246)
75 (246)
75 (246)
100 (328)
150 (492)
Degree of protection
IP20
IP20
IP20
IP20
IP20
Dimensions
• Width
mm (in)
50 (1.97)
50 (1.97)
50 (1.97)
50 (1.97)
100 (3.94)
• Height
mm (in)
380 (14.96)
380 (14.96)
380 (14.96)
380 (14.96)
380 (14.96)
• Depth
mm (in)
270 (10.6)
270 (10.6)
270 (10.6)
270 (10.6)
270 (10.6)
Weight, approx.
kg (lb)
4.6 (10.14)
4.6 (10.14)
4.6 (10.14)
4.6 (10.14)
7.9 (17.4)
1)
Rated power of a typical standard asynchronous (induction) motor at
600 V DC link voltage.
2)
Rated DC link current for dimensioning an external DC connection.
3)
With reinforced DC link busbar set, 150 A is possible (accessories).
4)
If, due to a number of Line Modules and Motor Modules being mounted
side-by-side, the current carrying capacity exceeds 20 A, an additional
24 V DC connection using a 24 V terminal adapter is required (max.
cross-section 6 mm
2
, max. fuse protection 20 A).
5)
Power loss of Motor Module at rated power including losses of 24 V DC
electronics power supply.
6)
At max. motor cable length 30 m (98.43 ft), pulse frequency 4 kHz and
DC link voltage 540 ... 600 V.
7)
Connector not included in scope of supply,
see Accessories
.
© Siemens AG 2017