SIEMENS
7/67
Siemens D 21.4 · 2017
SINAMICS S120 drive system
Booksize format
Single Motor Modules in booksize compact format
7
■
Technical specifications
DC link voltage 510 ... 720 V DC
Single Motor Module in booksize compact format
Internal air cooling
6SL3420-1TE13-0AA1
6SL3420-1TE15-0AA1
6SL3420-1TE21-0AA1
6SL3420-1TE21-8AA1
Output current
• Rated current
I
rated
A
3
5
9
18
• Base-load current
I
H
A
2.6
4.3
7.7
15.3
• For S6 duty (40 %)
I
S6
A
3.5
6
10
24
•
I
max
A
9
15
27
54
Type rating
1)
• Based on
I
rated
kW (hp)
1.6 (1.5)
2.7 (3)
4.8 (5)
9.7 (10)
• Based on
I
H
kW (hp)
1.4 (1)
2.3 (2.5)
4.1 (5)
8.2 (10)
Rated pulse frequency
kHz
8
8
4
4
DC link current
I
d
2)
A
3.6
6
11
22
Current carrying capacity
• DC link busbars
A
100
100
100
100
• 24 V DC busbars
3)
A
20
20
20
20
DC link capacitance
μ
F
110
110
110
235
Current requirement
At 24 V DC, max.
A
0.85
0.85
0.85
0.85
Power loss
kW
0.07
0.1
0.1
0.18
Cooling air requirement
m
3
/s
(ft
3
/s)
0.008 (0.3)
0.008 (0.3)
0.008 (0.3)
0.008 (0.3)
Sound pressure level
L
pA
(1 m)
dB
<60
<60
<60
<60
Motor connection
U2, V2, W2
Connector (X1) with
screw-type terminals
Connector (X1) with
screw-type terminals
Connector (X1) with
screw-type terminals
Connector (X1) with
screw-type terminals
• Conductor cross-section
mm
2
0.2 ... 6
0.2 ... 6
0.2 ... 6
0.2 ... 6
Shield connection
Integrated in connector
(X1)
Integrated in connector
(X1)
Integrated in connector
(X1)
Integrated in connector
(X1)
PE connection
M5 screw
M5 screw
M5 screw
M5 screw
Motor brake connection
Connector (X11),
24 V DC, 2 A
Connector (X11),
24 V DC, 2 A
Connector (X11),
24 V DC, 2 A
Connector (X11),
24 V DC, 2 A
Motor cable length, max.
• Shielded
m (ft)
50 (164)
50 (164)
50 (164)
70 (230)
• Unshielded
m (ft)
75 (246)
75 (246)
75 (246)
100 (328)
Degree of protection
IP20
IP20
IP20
IP20
Dimensions
• Width
mm (in)
50 (1.97)
50 (1.97)
50 (1.97)
75 (2.95)
• Height
mm (in)
270 (10.63)
270 (10.63)
270 (10.63)
270 (10.63)
• Depth
mm (in)
226 (8.90)
226 (8.90)
226 (8.90)
226 (8.90)
Weight, approx.
kg (lb)
2.7 (5.95)
2.7 (5.95)
2.7 (5.95)
3.4 (7.50)
1)
Rated power of a typical standard asynchronous (induction) motor at
600 V DC link voltage.
2)
Rated DC link current for dimensioning an external DC connection.
For DC link current calculation for dimensioning the Line Module,
see section configuration notes.
3)
If, due to a number of Line Modules and Motor Modules being mounted
side-by-side, the current carrying capacity exceeds 20 A, an additional
24 V DC connection using a 24 V terminal adapter is required (max.
cross-section 6 mm
2
, max. fuse protection 20 A).
4)
Power loss of Motor Module at rated power including losses of 24 V DC
electronics power supply.
© Siemens AG 2017