SIEMENS
9/16
Siemens D 31 · 2015
9
SINAMICS S110 servo drives
0.12 kW to 90 kW (0.16 hp to 125 hp)
PM340 Power Modules in blocksize format
■
Technical specifications
1)
Note the correlation between max. output frequency, pulse frequency and
current derating.
Air-cooled PM340 Power Module in blocksize format
6SL3210-1S...
Line connection voltage
(up to 2000 m (6562 ft) above sea level)
200 V... 240 V 1 AC ±10 % (in operation -15 % < 1 min) or
380 ... 480 V 3 AC ±10 % (in operation -15 % <1 min)
Line
• Power Modules without integrated line filter
Grounded TN/TT systems and non-grounded IT systems
• Power Modules with integrated line filter
TN systems with grounded star point
Line frequency
47 ... 63 Hz
Line power factor
at rated power
• Fundamental power factor (cos
ϕ
1
)
>0.96
• Total (
λ
)
- 200 ... 240 V 1 AC
0.45 ... 0.7
- 380 ... 480 V 3 AC
0.65 ... 0.95
Overvoltage category
acc. to EN 60664-1
Class III
Precharging frequency
of the DC link, max.
1× every 30 s
DC link voltage, approx.
1.35 × line voltage
Output frequency
• Control type Servo
0 ... 330 Hz
1)
Electronics power supply
24 V DC -15 %/+20 %
Radio interference suppression
• Standard
No radio interference suppression
• With line filter
Category C2 acc. to EN 61800-3
Type of cooling
Forced air cooling by means of built-in fan
A ambient or coolant temperature (air)
in operation for line-side components, Power Modules
0 ... 40 °C (32 ... 104 °F) without derating,
> 40 ... 55 °C (>104 ... 131 °F),
see derating characteristics
Installation altitude
Up to 1000 m (3281 ft) above sea level without derating,
> 1000 ... 4000 m (3281 .. 13124 ft) above sea level
see derating characteristics
Conformity
CE (low-voltage and EMC Directives)
Approvals, according to
cULus
Safety Integrated
Safety Integrity Level 2 (SIL 2) according to IEC 61508,
Performance Level d (PL d) and Category 3 according to EN ISO 13849-1
Additional information is provided in chapter Highlights,
section Safety Integrated.
© Siemens AG 2014