SINAMICS G120D distributed inverters
0.75 kW to 7.5 kW (1 hp to 10 hp)
PM250D Power Modules
■
Integration
PM250D Power Modules communicate with the Control Unit via
the PM-IF interface.
PM250D Power Modules have the following interfaces as
standard:
•
PM-IF interface to connect the PM250D Power Module to the
Control Unit.
•
Motor connection via a HAN Q8 (connector) including control
of the motor brake and temperature sensor
•
Line supply connection via HAN Q4/2 (socket)
Connection diagram for PM250D Power Module with integrated line filter class A
PE
PE
L3
0 V
24 V
L2
L1
=
3 ~
M
=
3 ~
3 ~
3
2
1
PE
4
11
12
1
2
3
4
5
6
7
8
PE
U
V
W
*)
-
+
PE
-
+
L3
L2
L1
PE
*)
*)
*)
HAN Q8
HAN Q4/2
PE
PM-IF interface
Line filter
class A
380 V to 500 V 3 AC
Motor brake
G_D011_EN_00120b
Temperature
sensor
*)
Not used
ext. 24 V DC
required
1)
Potential refers to DC link.
Please consider this when selecting the
motor cable.
1)
1)
Power Module
PM250D
Control Unit