![](https://www.globalindustrialsupplies.eu/wp-content/uploads/2016/08/siemens-gallery-4-324x200.jpg)
5/116
Siemens D 31 · 2015
5
SINAMICS G120 standard inverters
0.37 kW to 250 kW (0.5 hp to 400 hp)
Supplementary system components
> Push-through mounting frame for PM230 and PM240-2 Power Modules
■
Overview
It is advisable to use an optionally available mounting frame to
install the push-through unit in a control cabinet. This mounting
frame includes the necessary seals and frame to ensure
compliance with degree of protection IP54.
If the Power Module is installed without use of the optional
mounting frame, the user is responsible for ensuring that the
requisite degree of protection is provided.
Tightening torque for fixing the mounting frame and the inverter:
3 ... 3.5 Nm.
■
Selection and ordering data
■
Overview
SINAMICS memory card (SD card)
The parameter settings for an inverter can be stored on the
SINAMICS SD card. When service is required, e.g. after the
inverter has been replaced and the data have been downloaded
from the memory card the drive system is immediately ready for
use again.
•
Parameter settings can be written from the memory card to the
inverter or saved from the inverter to the memory card.
•
Up to 100 parameter sets can be stored.
•
The memory card supports standard commissioning without
the use of an operator panel such as the IOP, BOP-2 or the
STARTER commissioning tools and SINAMICS Startdrive.
•
If firmware is stored on the memory card and a Control Unit is
installed, the firmware can be upgraded/downgraded during
power-up
1)
.
Note:
The memory card is not required for operation and does not
have to remain inserted.
Licenses can be optionally ordered for CU250S-2 Control Units
in order to implement safety technology and positioning capa-
bility via the SINAMICS SD card.
For further information, refer to
section "Control Units".
1)
You can find more information about firmware upgrades/downgrades on
the Internet at
■
Selection and ordering data
For further information about firmware V4.6:
For further information about firmware V4.6:
For further information about firmware V4.7:
Description
Article No.
Push-through mounting frame
• For PM230 and PM240-2 Power Modules
degree of protection IP20, push-through
variants
-
Frame size FSA
6SL3260-6AA00-0DA0
-
Frame size FSB
6SL3260-6AB00-0DA0
-
Frame size FSC
6SL3260-6AC00-0DA0
Supplementary system components
> Memory cards
Description
Article No.
SINAMICS SD card
512 MB
6SL3054-4AG00-2AA0
Optional firmware memory cards
SINAMICS SD card
512 MB + firmware V4.5
(Multicard V4.5)
6SL3054-7EF00-2BA0
SINAMICS SD card
512 MB + firmware V4.6
(Multicard V4.6)
6SL3054-7EG00-2BA0
SINAMICS SD card
512 MB + firmware V4.7
(Multicard V4.7)
6SL3054-7EH00-2BA0
© Siemens AG 2014