0.75 kW to 7.5 kW (1 hp to 10 hp)
CU240D-2 and CU250D-2 Control Units
■
Integration
Connection example for CU240D-2 DP and CU240D-2 DP-F Control Units
PM-IF interface
G_D011_EN_00371d
X01.1 Switched 0 V (2M)
X01.2 Unswitched 0 V (1M)
X01.3 Functional earth
X01.4 Unswitched +24 V (1L+)
X01.5 Switched +24 V (2L+)
X02.1 Switched 0 V (2M)
X02.2 Unswitched 0 V (1M)
X02.3 Functional earth
X02.4 Unswitched +24 V (1L+)
X02.5 Switched +24 V (2L+)
Voltage supply 24 V
X03.1 *)
X03.2 Data A (N)
X03.3 *)
X03.4 Data B (P)
X03.5 Functional earth
X04.1 *)
X04.2 Data A (N)
X04.3 *)
X04.4 Data B (P)
X04.5 Functional earth
PROFIBUS DP interface
OUT
IN
OUT
IN
X05.1 *)
24 V, 500 mA max.
X05.2 Digital output 1
X05.3 Switched 0 V (2M)
X05.4 Digital output 0
X05.5 Functional earth
Digital outputs
Encoder interface
X07.1 Unswitched 24 V (1L+)
X07.2 Digital input 1
X07.3 Unswitched 0 V (1M)
X07.4 Digital input 0
X07.5 Functional earth
X08.1 Unswitched 24 V (1L+)
X08.2 Digital input 3
X08.3 Unswitched 0 V (1M)
X08.4 Digital input 2
X08.5 Functional earth
X09.1 Unswitched 24 V (1L+)
X09.2 Digital input 5
X09.3 Unswitched 0 V (1M)
X09.4 Digital input 4
X09.5 Functional earth
Digital inputs
Analog inputs
24 V, 500 mA max.
HTL encoder
X06.2 Channel A
X06.3 Channel A'
X06.4 Channel B
X06.5 Channel B'
X06.6 Channel Z
X06.7 Channel Z'
X06.1 Unswitched +24 V
X06.8 Unswitched 0 V
X10.1 *
)
X10.2 +10 V
X10.3 Analog input 0
X10.4 Analog input 1
X10.5 *
)
X10.6 *
)
X10.7 Unswitched
X10.8 *
)
*
)
Not connected
Optical interface
Mini USB interface
ON
OFF
PROFIBUS ADDRESS DIP switch
PROFIBUS bus termination
OFF
ON
IOP Handheld
Memory
card
Control Unit
CU240D-2 DP
CU240D-2 DP-F
DI1
DI0
X7.2
X7.4
X7.3
24 V
X8.2
X8.4
X8.3
24 V
DI3
DI2
X9.2
X9.4
X9.3
24 V
DI5
DI4
(1)
Bit 1
(64)
(16) (32)
(2)
(4)
(8)
Bit 0
Bit 3
Bit 2
Bit 5
Bit 6
Bit 4
Power Module