![](https://www.globalindustrialsupplies.eu/wp-content/uploads/2016/08/siemens-gallery-4-324x200.jpg)
8/8
Siemens D 31 · 2015
8
SINAMICS G120D distributed inverters
0.75 kW to 7.5 kW (1 hp to 10 hp)
SINAMICS G120D distributed inverters
■
Technical specifications
Unless explicitly specified otherwise, the following technical
specifications are valid for all the following SINAMICS G120D
distributed inverter components listed here.
1)
In product packaging.
2)
For further general information,
see also chapter SINAMICS G120,
section Technical specifications, Compliance with standards.
3)
With shielded motor cable up to 15 m (49 ft).
SINAMICS G120D
Mechanical specifications
Vibratory load
• Transport acc. to EN 60721-3-2
1)
Class 1M2
• Operation acc. to EN 60721-3-3
Class 3M2
Shock load
• Transport acc. to EN 60721-3-2
1)
Class 1M2
• Operation acc. to EN 60721-3-3
Class 3M2
Ambient conditions
Degree of protection
IP65/UL Type 3
Protection class
According to EN 61800-5-1
Class III (PELV)
Touch protection
According to EN 61800-5-1
Class I (with protective conductor system)
Permissible ambient and coolant temperature (air)
during operation for Power Modules
-10 ... +40 °C (14 ... 104 °F) without derating
>40 ... 55 °C (104 ... 131 °F),
see derating characteristics
Permissible ambient and coolant temperature (air)
during operation for Control Units
-10 ... +55 °C (14 ... 131 °F) with derating
Limit values are determined by the Control Unit used
(>40 ... 55 °C (104 ... 131 °F)
see derating characteristics
)
up to 2000 m above sea level
Humidity, max.
95 % at 40 °C (104 °F)
Ambient temperature
• Storage
1)
acc. to EN 60068-2-1
-40 ... +70 °C (-40 ... +158 °F)
• Transport
1)
acc. to EN 60068-2-1
-40 ... +70 °C (-40 ... +158 °F)
• Operation acc. to EN 60068-2-2
-10 ... +40 °C (14 ... 104 °F) without derating
Environmental class/harmful chemical substances
• Operation acc. to EN 60721-3-3
Class 3C2
Degree of pollution acc. to EN 61800-5-1
2
Certification for fail-safe versions
• According to IEC 61508
SIL 2
• According to EN ISO 13849-1
PL d and Category 3
Standards
Compliance with standards
UL 508C (UL list number E121068), cUL, CE, C-Tick
CE marking, according to
Low-Voltage Directive 2006/95/EC
EMC Directive
2)
• Frame sizes FSA to FSC with integrated line filter class A
Category C2
3)
according to EN 61800-3
Note
:
The EMC product standard EN 61800-3 does not apply directly to a
frequency inverter but to a PDS (Power Drive System), which comprises
the complete circuitry, motor and cables in addition to the inverter. The
frequency inverters on their own do not generally require identification
according to the EMC Directive.
© Siemens AG 2014