SIEMENS
6/19
Siemens D 31 N · March 2016
6
SINAMICS G110M distributed inverters
0.37 kW to 4 kW (0.5 hp to 5 hp)
PM240M Power Modules
■
Technical specifications
General technical specifications
1)
Applies to Power Modules and Control Units in the mounted state.
2)
Applies to industrial control panel installations to NEC article 409 or
UL 508A.
PM240M Power Modules
System operating voltage
380 V (-10 %) ... 480 V (+10 %) 3 AC
Grid requirements
Short-circuit power ratio R
SC
>100
Input frequency
47 ... 63 Hz
Output frequency
• Control mode V/f
0 ... 550 Hz
• Control type Vector
0 ... 200 Hz
Pulse frequency
4 kHz (standard); 4 ... 16 Hz (in steps of 2 kHz)
see derating data
Power factor
0.95
Inverter efficiency
95 ... 97 %
Output voltage, max.
in % of the input voltage
87%
Overload capability
• High overload (HO)
0.37 ... 3 kW (0.5 ... 4 hp):
2 × rated output current for 3 s,
followed by 1.5 × rated output current for 57 s,
over a cycle time of 300 s (110 % on average)
4 kW (5 hp):
1.6 × rated output current for 3 s,
followed by 1.5 × rated output current for 57 s,
over a cycle time of 300 s (110 % on average)
Electromagnetic compatibility
Integrated line filter class A according to EN 55011
Possible braking methods
Dynamic brake with internal braking resistors (accessories)
Dynamic brake with external braking resistors
R
min
= 200
Ω
(for FSA),
R
min
= 60
Ω
(for FSB)
DC brake
Integrated brake control supplies DC power supply for the brake
Line input voltage
380 V AC
400 V AC
440 V AC
480 V AC
500 V AC
Resulting brake voltage
171 V DC
180 V DC
198 V DC
216 V DC
225 V DC
Disconnection on the DC side permits "fast" braking (max. output current 1 A)
Degree of protection
1)
IP66 (for Control Unit, screw-type version)
IP65 (for Control Units, plug-in version)
Operating temperature
-10 ... +55 °C (14 ... +131 °F)
Storage temperature
-40 ... +70 °C (-40 ... +158 °F)
Permissible mounting positions
All
Relative humidity
<95 % RH, condensation not permissible
Cooling
External cooling with motor fan
Installation altitude
Up to 1000 m (3281 ft) above sea level without derating
Over 1000 m (3281 ft)
see derating data
Short Circuit Current Rating
(SCCR)
2)
40 kA
Protection functions
• Undervoltage
• Phase failure detection
• Overvoltage
• Overload
• Ground fault
• Short-circuit
• Stall protection
• Motor blocking protection
• Motor overtemperature
• Inverter overtemperature
• Parameter locking
Compliance with standards
UL, cUL, CE, C-Tick (RCM)
CE marking, according to
EC Low Voltage Directive 73/23/EEC;
filtered variants also: EC Low Voltage Directive 89/336/EEC
© Siemens AG 2016