SIEMENS
6/13
Siemens D 31 N · March 2016
6
■
Integration
SINAMICS G110M distributed inverters
0.37 kW to 4 kW (0.5 hp to 5 hp)
CU240M Control Units
Connection diagram for CU240M DP Control Units
0
1
2
3
4
5
6
7
8
9
1
0
1
1
1
2
G_D011_EN_00436b
Optical interface
Mini USB interface
24 V DC voltage supply
PROFIBUS DP interface
Digital outputs
Digital inputs
Analog inputs
ON
PROFIBUS bus termination
PROFIBUS
ADDRESS DIP switch
OFF
ON
OFF
OUT
IN
OUT
IN
Potentio-
meter
X01.1 Switched 0 V (2M)
PROFIBUS DP
IN
PROFIBUS DP
OUT
24 V DC
(max. 500 mA)
X01.2 Unswitched 0 V (1M)
X01.3 Functional earth
X01.4 Unswitched +24 V (1L+)
X01.5 Switched +24 V (2L+)
X02.1 Switched 0 V (2M)
X02.2 Unswitched 0 V (1M)
X02.3 Functional earth
X02.4 Unswitched +24 V (1L+)
X02.5 Switched +24 V (2L+)
X03.1 Not connected
X03.2 Data A (N)
X03.3 Not connected
X03.4 Data B (P)
X03.5 Functional earth
X04.1 Not connected
X04.2 Data A (N)
X04.3 Not connected
X04.4 Data B (P)
X04.5 Functional earth
X05.1 Not connected
X05.2 Digital output 1
X05.3 Connected 0 V (2M)
X05.4 Digital output 0
X05.5 Functional earth
X07.1 Unswitched 24 V (1L+)
X07.2 Digital input 1
X07.3 Unswitched0 V (1M)
X07.4 Digital input 0
X07.5 Functional earth
X08.1 Unswitched 24 V (1L+)
X08.2 Digital input 3
X08.3 Unswitched0 V (1M)
X08.4 Digital input 2
X08.5 Functional earth
X10.1 Not connected
X10.2 +10 V
X10.3 Analog input 0 +
X10.4 Analog input 1 +
X10.5 Analog input 0 -
X10.6 Analog input 1 -
X10.7 Unswitched 0 V
X10.8 Not connected
PM-IF interface
24 V DC
voltage
supply
IN
24 V DC
voltage
supply
OUT
IOP Handheld
Memory
card
Control Unit
CU240M DP
(1)
Bit 1
(64)
(16) (32)
(2)
(4)
(8)
Bit 0
Bit 3
Bit 2
Bit 5
Bit 6
Bit 4
Power
Module
DI1
DI3
X7.2
X8.2
X8.4
X8.3
X7.4
X7.3
24V
24V
DI0
DI2
© Siemens AG 2016