SIEMENS
5/94
Siemens D 31 N · March 2016
SINAMICS G120 standard inverters
0.37 kW to 250 kW (0.5 hp to 400 hp)
Line-side components
> Recommended line-side power components
5
380 ... 480 V 3 AC
(continued)
45
60
1PE28-8 . L0
FSE
125
3NE1022-0
3VL1712-2DD33-
....
*)
J
125
55
75
1PE31-1 . L0
FSE
160
3NE1224-0
3VL1716-2DD33-
....
*)
J
150
75
100
1PE31-5 . L0
FSF
200
3NE1225-0
3VL3720-3DC33-
....
*)
J
200
90
125
1PE31-8 . L0
FSF
250
3NE1227-0
3VL3725-3DC33-
....
*)
J
225
110
150
1PE32-1 . L0
FSF
315
3NE1230-0
3VL4731-3DC36-
....
*)
J
300
132
200
1PE32-5 . L0
FSF
350
3NE1331-0
3VL4740-3DC36-
....
*)
J
350
500 ... 690 V 3 AC
11
10
1PH21-4 . L0
FSD
25
3NE1815-0
3RV1042-4BA10
J
20
15
15
1PH22-0 . L0
FSD
25
3NE1815-0
3RV1042-4EA10
J
25
18.5
20
1PH22-3 . L0
FSD
35
3NE1803-0
3RV1042-4EA10
J
30
22
25
1PH22-7 . L0
FSD
35
3NE1803-0
3VL1704-2DD33-
....
*)
J
35
30
30
1PH23-5 . L0
FSD
50
3NE1817-0
3VL1705-2DD33-
....
*)
J
45
37
40
1PH24-2 . L0
FSD
63
3NE1818-0
3VL1706-2DD33-
....
*)
J
60
45
50
1PH25-2 . L0
FSE
80
3NE1820-0
3VL1708-2DD33-
....
*)
J
80
55
60
1PH26-2 . L0
FSE
80
3NE1820-0
3VL1710-2DD33-
....
*)
J
80
75
75
1PH28-0 . L0
FSF
100
3NE1021-0
3VL1712-2DD33-
....
*)
J
100
90
100
1PH31-0 . L0
FSF
125
3NE1022-0
3VL1712-2DD33-
....
*)
J
125
110
100
1PH31-2 . L0
FSF
160
3NE1224-0
3VL1716-2DD33-
....
*)
J
150
132
125
1PH31-4 . L0
FSF
200
3NE1225-0
3VL3720-3DC33-
....
*)
J
200
Rated power
1)
PM240-2
Power Module
push-through variant
IEC-compliant
UL/cUL-compliant
Fuse
Circuit breaker
Fuse type
Rated voltage 250 V AC or
600 V AC
Type
Current
Current
kW
hp
6SL3211-...
Frame size
A
Article No.
Article No.
Class
A
200 ... 240 V 1 AC/3 AC
0.75
1
1PB13-8 . L0
FSA
16
3NA3805
3RV2011-4AA10
J, T, CC, G, CF
15
2.2
3
1PB21-0 . L0
FSB
32
3NA3812
3RV2021-4EA10
J, T, CC, G, CF
35
4
5
1PB21-8 . L0
FSC
50
3NA3820
3RV1031-4HA10
J, T, CC, G, CF
50
380 ... 480 V 3 AC
3
4
1PE18-0 . L1
FSA
16
3NA3805
3RV2011-4AA10
J, T, CC, G, CF
30
7.5
10
1PE21-8 . L0
FSB
32
3NA3812
3RV2021-4EA10
J, T, CC, G, CF
35
15
20
1PE23-3 . L0
FSC
50
3NA3820
3RV1031-4HA10
J, T, CC, G, CF
50
Rated power
1)
PM240-2
Power Module
standard variant
IEC-compliant
UL/cUL-compliant
Fuse
Circuit breaker
Fuse type
Rated voltage 250 V AC or
600 V AC
Type
Current
Current
kW
hp
6SL3210-...
Frame size
A
Article No.
Article No.
Class
A
1)
Rated power based on the rated output current
I
rated
. The rated
output current
I
rated
is based on the duty cycle for low overload (LO).
*)
See Catalog LV 10 for Article No. supplements.
■
Selection and ordering data
© Siemens AG 2016