SIEMENS
5/36
Siemens D 31 N · March 2016
SINAMICS G120 standard inverters
0.37 kW to 250 kW (0.5 hp to 400 hp)
Control Units
5
Integrated bus interface
USS, Modbus RTU
RS485 connected at a terminal,
isolated, bus terminating resistor
can be switched in, slave address
can be set using DIP switches
USS: max. 187.5 kBaud
Modbus RTU:19.2 kBaud
CU230P-2 HVAC
6SL3243-0BB30-1HA3
CU240B-2
6SL3244-0BB00-1BA1
CU240E-2
6SL3244-0BB12-1BA1
CU240E-2 F
6SL3244-0BB13-1BA1
CU250S-2
6SL3246-0BA22-1BA0
BACnet MS/TP, FLN P1 protocol
RS485 connected to a terminal,
isolated, bus terminating resistor
can be switched in
Max. 187.5 kBaud
CU230P-2 HVAC
6SL3243-0BB30-1HA3
–
–
–
PROFIBUS DP
-
PROFIdrive profile
9-pin SUB-D socket, isolated,
PROFIdrive profile V4.1, slave
address can be set using DIP
switches
Max. 12 Mbit/s
CU230P-2 DP
6SL3243-0BB30-1PA3
CU240B-2 DP
6SL3244-0BB00-1PA1
CU240E-2 DP
6SL3244-0BB12-1PA1
incl. PROFIsafe
CU240E-2 DP-F
6SL3244-0BB13-1PA1
incl. PROFIsafe
CU250S-2 DP
6SL3246-0BA22-1PA0
incl. PROFIsafe
PROFINET
-
PROFIdrive profile
-
PROFIenergy profile
2 × RJ45, PROFIdrive profile V4.1,
device name can be stored on the
device
Max. 100 Mbit/s (full duplex)
CU230P-2 PN
6SL3243-0BB30-1FA0
–
CU240E-2 PN
6SL3244-0BB12-1FA0
incl. PROFIsafe
CU240E-2 PN-F
6SL3244-0BB13-1FA0
incl. PROFIsafe
CU250S-2 PN
6SL3246-0BA22-1FA0
incl. PROFIsafe
EtherNet/IP
-
ODVA AC drive
-
- SINAMICS profile
CU230P-2 PN
6SL3243-0BB30-1FA0
–
CU240E-2 PN
6SL3244-0BB12-1FA0
CU240E-2 PN-F
6SL3244-0BB13-1FA0
CU250S-2 PN
6SL3246-0BA22-1FA0
CANopen
9-pin SUB-D connector, isolated,
slave address can be set using DIP
switches,
bus terminating resistor can be
switched in
Max. 1 Mbit/s
–
–
–
CU250S-2 CAN
6SL3246-0BA22-1CA0
Tool interfaces
Memory card
SINAMICS SD card
Operator panels
• IOP
supported connection options between Control Unit and IOP:
Can be directly plugged on, door mounting or handheld
• BOP-2
Supported connection options between Control Unit and BOP-2:
can be directly plugged on or door-mounted
PC interface
USB (connection via PC inverter connection kit 2)
Open-loop/closed-loop control techniques
V/f linear/square/parameterizable
V/f with flux current control (FCC)
V/f ECO; linear/square-law
Vector control, sensorless
Vector control, with sensor
–
–
–
Torque control, sensorless
Torque control, with sensor
–
–
–
Software functions
Application macro
Setpoint input, can be
parameterized
Fixed frequencies
16, parameterizable
JOG
Digital motorized potentiometer
(MOP)
Ramp smoothing
Extended ramp-function genera-
tor (with ramp smoothing OFF3)
Slip compensation
Control Unit
CU230P-2 series
6SL3243-0BB30-1 . A3
6SL3243-0BB30-1FA0
CU240B-2 series
6SL3244-0BB00-1 . A1
CU240E-2 series
6SL3244-0BB1 . -1 . A1
6SL3244-0BB1 . -1FA0
CU250S-2 series
6SL3246-0BA22-1 . A0
■
Technical specifications
© Siemens AG 2016