SIEMENS
4/18
Siemens D 31 N · March 2016
4
SINAMICS G120C compact inverters
0.55 kW to 18.5 kW (0.75 hp to 25 hp)
SINAMICS G120C compact inverters
■
Dimensional drawings
SINAMICS G120C, frame size FSAA
Mounted with 2 M4 bolts, 2 M4 nuts, 2 M4 washers.
When the shield plate is mounted, the drilling pattern is compatible with frame size FSA.
Ventilation clearance required at the top: 80 mm
(3.15 inches)
.
Ventilation clearance required at the bottom: 100 mm
(3.94 inches)
.
Ventilation clearance required at the side: 0 mm
(0 inches).
When the IOP is inserted, the mounting depth increases by 21 mm
(0.83 inches)
.
When the BOP-2 is inserted, the mounting depth increases by 11 mm
(0.43 inches)
.
All dimensions in mm
(values in brackets are in inches)
.
SINAMICS G120C, frame size FSA
Mounted with 3 M4 studs, 3 M4 nuts, 3 M4 washers.
Ventilation clearance required at the top: 80 mm
(3.15 inches)
.
Ventilation clearance required at the bottom: 100 mm
(3.94 inches)
.
Ventilation clearance required at the side: 0 mm
(0 inches).
When the IOP is inserted, the mounting depth increases by 21 mm
(0.83 inches)
.
When the BOP-2 is inserted, the mounting depth increases by 11 mm
(0.43 inches)
.
All dimensions in mm
(values in brackets are in inches)
.
160
(6.3)
73
(2.87)
155
(6.1)
PN version: 177.4
(6.98)
Ø4.5
(0.18)
Drill
pattern
G_D011_EN_00476
173
(6.81)
186
(7.32)
196
(7.72)
73
(2.87)
203
(7.99)
62.3
(2.45)
Ø4.5
(0.18)
Drill
pattern
G_D011_EN_00344a
PN version: 225.4
(8.87)
© Siemens AG 2016