SIEMENS
5/71
Siemens D 31 N · March 2016
SINAMICS G120 standard inverters
0.37 kW to 250 kW (0.5 hp to 400 hp)
Power Modules
5
■
Technical specifications
PM240 Power Modules
Line voltage 380 ... 480 V 3 AC
PM240 Power Modules
Without integrated line filter
6SL3224-0XE41-3UA0
6SL3224-0XE41-6UA0
6SL3224-0XE42-0UA0
Output current
at 50 Hz 400 V 3 AC
• Rated current
I
rated
1)
A
302
370
477
• Base-load current
I
L
1)
A
302
370
477
• Base-load current
I
H
2)
A
250
302
370
• Maximum current
I
max
A
400
483
592
Rated power
• Based on
I
L
kW (hp)
160 (250)
200 (300)
250 (400)
• Based on
I
H
kW (hp)
132 (200)
160 (250)
200 (300)
Rated pulse frequency
kHz
2
2
2
Efficiency
η
>0.98
>0.98
>0.98
Power loss
3)
At rated current
kW
4.163
4.783
5.911
Cooling air requirement
m
3
/s (ft
3
/s)
0.36 (12.7)
0.36 (12.7)
0.36 (12.7)
Sound pressure level
L
pA
(1 m)
dB
<69
<69
<69
24 V DC power supply
for Control Unit
A
1
1
1
Rated input current
4)
• With line reactor
A
245
297
354
• Without line reactor
A
297
354
442
Length of cable to braking
resistor, max.
m (ft)
50 (164)
50 (164)
50 (164)
Line supply connection
U1/L1, V1/L2, W1/L3
M10 screw stud
M10 screw stud
M10 screw stud
• Conductor cross-section
mm
2
2 × 240
2 × 240
2 × 240
Motor connection
U2, V2, W2
M10 screw stud
M10 screw stud
M10 screw stud
• Conductor cross-section
mm
2
2 × 240
2 × 240
2 × 240
PE connection
On housing with M10 screw
On housing with M10 screw
On housing with M10 screw
Motor cable length
5)
, max.
• Shielded
m (ft)
200 (656)
200 (656)
200 (656)
• Unshielded
m (ft)
300 (984)
300 (984)
300 (984)
Degree of protection
IP20
IP20
IP20
Dimensions
• Width
mm (in)
326 (12.83)
326 (12.83)
326 (12.83)
• Height
mm (in)
1533 (60.35)
1533 (60.35)
1533 (60.35)
• Depth
mm (in)
547 (21.54)
547 (21.54)
547 (21.54)
Frame size
FSGX
FSGX
FSGX
Weight, approx.
kg (lb)
174 (384)
174 (384)
174 (384)
1)
The rated output current
I
rated
and the base-load current
I
L
are based on
the duty cycle for low overload (LO).
2)
The base-load current
I
H
is based on the duty cycle for high overload
(HO).
3)
Typical values. You can find additional information on the Internet at
4)
The input current depends on the motor load and line impedance. The
input currents apply for a load at rated power (based on
I
rated
) for a line
impedance corresponding to
u
K
= 1 %. These current values without line
reactor are specified on the rating plate of the Power Module.
5)
Max. motor cable length 25 m (82 ft) (shielded) for PM240 Power Modules
with integrated line filter to maintain the limit values acc.to EN 61800-3
Category C2.
© Siemens AG 2016