SIEMENS
01/28/2015
2
Corrections
© Siemens AG 2015
SINAMICS GM150 SINAMICS SM150
Supplement for Catalog D 12 2012
7
2
Corrections
Table 1-1
Corrections for the 2012 edition of catalog D 12
Page
Content of 2012 edition
Correction
2/11
3/9
4/9
5/12
2/19
3/15
4/14
5/18
Other ambient conditions
Operation
Biological ambient conditions
in accordance with Class
3B2
…
Chemically active substances
in accordance with Class
3C2
…
3B1
…
3C1
…
3/17
Deionized water requirement in l, approx.
6SL3835-2LN41-8AA0
135
6SL3835-2LN42-8AA0
170
6SL3835-2LN43-6AA0
170
6SL3835-2LN44-2AA0
255
35
70
70
105
5/20 to
5/22
Deionized water requirement in l, approx.
6SL3845-7NN41-8AA0
150
6SL3845-7NN43-6AA0
250
6SL3845-7NN45-4AA0
300
6SL3845-7NN41-8AB0
225
6SL3845-7NN41-8AC0
250
6SL3845-7NN41-8AD0
275
6SL3845-7NN41-8AF0
275
6SL3845-7NN41-8AG0
300
6SL3845-7NN41-8AK0
350
6SL3845-7NN43-6AF0
300
6SL3845-7NN42-2AA0
150
6SL3845-7NN44-5AA0
250
6SL3845-7NN46-7AA0
300
50
100
150
75
100
125
125
150
175
150
50
100
150
6/21
K80
Control of "Safe Torque Off" function
(SINAMICS SM150; SINAMICS GM150
on
request)
…
In conjunction with external circuitry, the "Safe
Torque Off" function has been certified by TÜV-Süd
[German Technical Inspectorate] in accordance with
EN ISO 13849-1 with Safety Category 3 and
Performance Level d as well as EN 61508 (IEC
61508), Parts 1 to 4, SIL 2.
…
…
In conjunction with external circuitry, the "Safe
Torque Off" function has been certified by TÜV-Süd
[German Technical Inspectorate] in accordance with
EN ISO 13849-1 with Safety Category 3 and
Performance Level d as well as EN 61508
:2000
(IEC
61508
:2000
), Parts 1 to 4, SIL 2
(issue date of
certificate: 2012-09-20)
.
…