SIEMENS
Engineering information
SINAMICS GM150, SINAMICS SM150
Overview of interfaces
9/3
Siemens D 12 · 2012
9
■
Overview of connections for SINAMICS GM150
I>
I>>
=.LD-A11:
1T1
1T2
1T3
2T1
2T2
2T3
3T1
3T2
3T3
=.LC-A21:
=.LC-A22:
=.LC-A41:
=.LC-A42:
1
2
1
2
5
6
5
6
X522:
2
3
4
5
6
7
8
9
X521:
2
3
4
5
6
7
8
9
X520:
2
3
4
5
6
7
8
9
=.HC-A31
L1
L2
L3
L1
N
1
3
5
1
2
17 A
=.LA-X11
=.EF-X21
T
VSM10
1U2
1V2
1W2
SMC30
CB
L-
L+
U<
=.LA-X52
1U1
1V1
1W1
2U1
2V1
2W1
ASM
L1
L2
L3
PE
1
2
3
PE
-X1
M
3~
L1
L2
L3
L1
N
L1
N
1
2
3
1
2
1
2
3
4
7
8
9
10
4
5
6
L
N
PE
-X3
1
2
3
=.EF-X21
=.EF-X22
8
8
Main setpoint speed
Additional setpoint speed
Main actual value speed
Additional actual value speed
G_D012_EN_00036a
External safety circuit
=.EF-X21:
=.LA-X11
ON
OFF
PT100 sensor 1
PT100 sensor 2
PT100 sensor 3
Instrumentation and control interface
1A
ON command
2A
to circuit-breaker
3A
ON command
4A
to circuit-breaker
7A
OFF command
9A
to circuit-breaker
11A
Tripping of undervoltage coil
12A
of circuit-breaker
13A
OFF command to the second OFF coil
15A
of the circuit-breaker
1A
Circuit-breaker ready
to start checkback
2A
Circuit-breaker OFF checkback
3A
Circuit-breaker ON checkback
4A
Circuit-breaker OFF externally
checkback
Control bit 2 command (setpoint lower)
Control bit 3 command (selection fixed setpoint bit 0)
Control bit 4 command (selection fixed setpoint bit 1)
Select command data bit 0
Switching of direction
Ready to start message
Ready to operate message
Operation message
Converter fault message
Converter alarm message
Local/remote operation state message
Drive rotates right message
Free
Free
Free
Free
EMERGENCY STOP on
1A
converter
2A
OFF command to
circuit-breaker
Auxiliary supply 400 V 3 AC
=.EA-Q11:
Auxiliary supply 230 V 1 AC
=.EB-X1:
=.LC-A21:
Incorporation of an externally arranged
EMERGENCY STOP button
=.LA-X51:
Option K50
Speed measurement
Option L32 automatic restart
SINAMICS GM150
Options N30 to N33
Controlled outgoing feeder for
auxiliaries 400 V 3 AC
=.GC-X1:
Options N35 to N38
Controlled outgoing feeder for
auxiliaries 230 V 1 AC
=.GC-X1:
Example:
external fan of
forced-cooled
motor
Example:
anti-condensation
heating in motor
Auxiliaries ON checkback
=.GC-X2:
External supply ON
circuit-breaker
=.GC-X2:
Option L50
Cabinet lighting and service socket outlet
in control section
=.EG-X1:
Cooling unit
(water-cooled version)
Auxiliary supply 400 V 3 AC / 230 V 1 AC
400 V 3 AC (coolant pumps)
230 V 1 AC (control)
P24
M
OFF command to superordinate
circuit-breaker
11
12
13
Note:
This is an overview
connection diagram.
For detailed plant
configuration, see
interface diagrams.
Free
ON/OFF 1
OFF 2
OFF 3
Acknowledgement
Free
Inverter release
Control bit 1 command (setpoint higher)
18
19
18
19
=.EF-X22:
© Siemens AG 2012