SIEMENS
SINAMICS G180
SINAMICS G180 cabinet units
SINAMICS G180 cabinet units
air-cooled and liquid-cooled
3/14
Siemens D 18.1 · 2014
3
■
Technical data
(continued)
500 V, 6-pulse
Line voltage, supply system type
400, 415, 460,
500
V 3 AC IT/TT/TN
SINAMICS G180
cabinet units – air-cooled
6SE0180-
1BD33-7
■
A7
6SE0180-
1BD34-6
■
A7
6SE0180-
1BD36-3
■
A7
6SE0180-
1BD37-3
■
A7
6SE0180-
1BD38-2
■
A7
Converter type
(air-cooled)
2T3A-87501-250
2T3A-87501-315
2T3A-87501-400
2T3A-87501-500
2T3A-87501-560
SINAMICS G180
cabinet units – liquid-cooled
6SE0170-
1BD33-7
■
A7
6SE0170-
1BD34-6
■
A7
6SE0170-
1BD36-3
■
A7
6SE0170-
1BD37-3
■
A7
6SE0170-
1BD38-2
■
A7
Converter type
(liquid-cooled)
2T6A-77501-250
2T6A-77501-315
2T6A-77501-400
2T6A-77501-500
2T6A-77501-560
Electrical data at motor end
Type rating
1)
• at 50 Hz 500 V
kW
250
315
400
500
560
• at 60 Hz 460 V
hp
309
389
494
617
691
Output voltage
2)
V
0 ... 0.98 ×
V
line
0 ... 0.98 ×
V
line
0 ... 0.98 ×
V
line
0 ... 0.98 ×
V
line
0 ... 0.98 ×
V
line
Output current
• Continuous current
A
370
460
640
730
820
• Short-time current
(60 s every 10 minutes) max.
A
450
560
700
900
980
Overload capability
(60 s every 10 minutes) max.
%
22
22
9
23
20
Output power
kVA
320
398
554
632
710
Output frequency, max.
Hz
250
250
250
120
120
Rated clock cycle
kHz
3
3
2.4
2.4
2.4
adjustable from
kHz
2 ... 5
2 ... 5
1.5 ... 3.7
1.5 ... 3.7
1.5 ... 3.7
Power loss
3)
kW
6.15
7.39
9.37
12.8
13.7
Rated efficiency
%
97.7
97.8
97.8
97.6
97.7
Electrical data at line end
Connected load
kVA
303
378
515
606
678
Rated input voltage
V
500
500
500
500
500
Input current
• Continuous line current
A
350
437
595
700
783
• Short-time line current (60 s) max.
A
426
532
651
863
936
Line fuse (provided by customer)
gL (A)
400
500
630
800
800
λ
line
0.918
0.916
0.936
0.942
0.944
Cos
ϕ
line
1
1
1
1
1
Radio interference suppression
acc. to EN 61800-3
4)
C3 (class A filter)
C3 (class A filter)
C3 (class A filter)
C3 (class A filter)
C3 (class A filter)
Mechanical data for air-cooled cabinet units
Frame size
(dimensional drawing classification)
SL2
SL2
SL2
SL21
SL3
Sound pressure level
L
pA
(1 m) at 50/60 Hz
dB
70
73
73
75
75
Standard converter dimensions
• Width
mm
806
806
806
1206
1606
• Height
5)
mm
2112
2112
2112
2112
2112
• Depth
mm
605
605
605
605
605
Coolant requirements
m
3
/h
1900
1900
1900
2250
3200
Weight, approx.
kg
490
510
530
780
890
Mechanical data for liquid-cooled cabinet units
Frame size
(dimensional drawing classification)
SW2
SW2
SW2
SW21
SW3
Sound pressure level
L
pA
(1 m) at 50/60 Hz
dB
68
71
71
73
73
Standard converter dimensions
• Width
mm
806
806
806
1206
1806
• Height
mm
2202
2202
2202
2202
2202
• Depth
mm
605
605
605
605
605
Coolant requirements
l/h
1200
1200
1200
1200
2000
Min. coolant pressure
bar
2.5
2.5
2.5
2.5
2.5
Max. coolant pressure
bar
6
6
6
6
6
Coolant test pressure
bar
10
10
10
10
10
Coolant pressure loss
bar
1.9
1.9
1.9
1.9
1.9
Min. coolant temperature
°C
10
10
10
10
10
Max. coolant temperature
°C
35
35
35
30
35
Weight, approx.
kg
490
510
530
850
920
For footnotes, see next page.
© Siemens AG 2014