SIEMENS
SINAMICS G180
SINAMICS G180 compact units and SINAMICS G180 cabinet systems
SINAMICS G180 cabinet systems
2/40
Siemens D 18.1 · 2014
2
■
Options
(continued)
Additional
ordering data
-Z
with order
code and, if
necessary,
with plain text
specification
SINAMICS G180 cabinet systems (compact units installed in a control cabinet)
690 V TN/TT system
690 V IT system
Version – see selection and ordering data
Option text
M
N
O
P
Q
R
S
T
U
V
Output filter
Strengthened
d
v
/d
t
output filter for max.
250/300 m (type-dependent). Design for
longer motor cables available on request
L10
H82
3)
H82
3)
Sine-wave filter integrated in control
cabinet, suitable for motor frequencies of
≤
75 Hz, voltage drop of approximately
5 % of line voltage
L17
H81
3)
+
H92
3)
H81
3)
+
H92
3)
Standard accessories packages
Peripheral board 4 (G05) instead of
peripheral board 2 (G03) (only in con-
junction with package S01, S02, S03, S04,
S08, S09, S11, S12)
G08
Accessories package S01 with main
switch, line contactor, EMERGENCY OFF
pushbutton and safety relay, board G03,
local/remote switch
S01
Accessories package S02 with circuit
breaker, line contactor, EMERGENCY OFF
pushbutton and safety relay, board G03,
local/remote switch
S02
Accessories package with main switch,
line contactor, board G03, local/remote
switch
S03
Accessories package with circuit breaker,
line contactor, board G03, local/remote
switch
S04
Accessories package with main switch,
line contactor, Calomat, RCU box
connection
S06
Bypass for smooth line synchronization
(soft start function) incl. line-side main
switch and contactors at the converter
output and in bypass
S08
H82
3)
H83
3)
H82
3)
H83
3)
Bypass for smooth line synchronization
(soft start function) incl. line-side circuit
breaker and contactors at the converter
output and in bypass
S09
H82
3)
H83
3)
H82
3)
H83
3)
Accessories package S11 with line-side
main switch, board G03, local/remote switch
S11
Accessories package S12 with line-side cir-
cuit breaker, board G03, local/remote switch
S12
Bypass with line-side main switch,
contactors at converter output and in
bypass, switchover between manual
and automatic, local/remote switch
S21
H82
3)
H83
3)
H82
3)
H83
3)
Bypass with line-side circuit breaker,
contactors at converter output and in
bypass, switchover between manual
and automatic, local/remote switch
S22
H82
3)
H83
3)
H82
3)
H83
3)
Bypass with line-side main switch,
contactors at converter output and in
bypass, EMERGENCY OFF safety relay,
switchover between manual and
automatic, local/remote switch
S23
H82
3)
H83
3)
H82
3)
H83
3)
Bypass with line-side circuit breaker,
contactors at converter output and in
bypass, EMERGENCY OFF safety relay,
switchover between manual and auto-
matic, local/remote switch
S24
H82
3)
H83
3)
H82
3)
H83
3)
NAMUR accessories package with Test/
Normal operation switch, option G05,
terminal strip compliant with
NAMUR NE37 (without main switch)
S31
NAMUR accessories package with Test/
Normal operation switch, main switch,
line contactor, option G05, terminal strip
compliant with NAMUR NE37
S32
For legends and footnotes, see Page 2/45.
© Siemens AG 2014