SIEMENS
SINAMICS G180
SINAMICS G180 compact units and SINAMICS G180 cabinet systems
SINAMICS G180 compact units
2/13
Siemens D 18.1 · 2014
2
■
Technical data
(continued)
690 V, 6-pulse
(continued)
Line voltage, supply system type
230 ... 690 V 3 AC, TT/TN or IT
SINAMICS G180
compact units
6SE0100-
1A
■
24-2
■
A7
6SE0100-
1A
■
25-0
■
A7
6SE0100-
1A
■
25-8
■
A7
6SE0100-
1A
■
28-0
■
A7
6SE0100-
1A
■
31-0
■
A7
Converter type
2T2A-07600-037
2T2A-07600-045
2T2A-07600-055
2T2A-07600-075
2T2A-07600-090
Electrical data at motor end
Type rating
1)
• at 50 Hz 690 V
kW
37
45
55
75
90
• at 60 Hz 575 V
hp
41
50
62
84
101
Output voltage
2)
V
0 ... 0.98 ×
V
line
0 ... 0.98 ×
V
line
0 ... 0.98 ×
V
line
0 ... 0.98 ×
V
line
0 ... 0.98 ×
V
line
Output current
• Continuous current
A
43
50
60
80
95
• Short-time current
(60 s every 10 minutes) max.
A
55
65
75
90
120
Overload capability
(60 s every 10 minutes) max.
%
28
30
25
13
26
Output power
kVA
51.4
59.8
71.7
95.6
114
Output frequency, max.
Hz
250
250
250
250
250
Rated clock cycle
kHz
3
3
3
3
3
adjustable from
kHz
2 ... 5
2 ... 5
2 ... 5
2 ... 5
2 ... 5
Power loss
3)
kW
1.19
1.44
1.68
2.28
2.63
Rated efficiency
%
97.1
97.1
97.2
97.2
97.3
Electrical data at line end
Connected load
kVA
16
24.4
32
39.2
52.3
Rated input voltage
V
690
690
690
690
690
Input current
• Continuous line current
A
42.9
50.1
60.7
80.9
102
• Short-time line current (60 s)
max.
A
55
65
76
91
129
Line fuse
(provided by customer)
gL (A)
50 ... 63
63
63 ... 80
100
125
λ
line
0.898
0.863
0.894
0.896
0.845
Cos
ϕ
line
1
1
1
1
1
Radio interference suppres-
sion acc. to EN 61800-3
4)
C2 (class A filter)
C2 (class A filter)
C2 (class A filter)
C2 (class A filter)
C2 (class A filter)
Mechanical data
Coolant requirements
m
3
/h
750
750
750
750
1050
Sound pressure level
L
pA
(1 m) at 50/60 Hz
dB
60
60
60
60
62
Max. cable length between
converter and motor with
standard insulation
• (shielded)
m
300
5)
300
5)
300
5)
300
5)
150 (300)
6)
Line/load connection
L1, L2, L3/U2, V2, W2
For connection cross-sections,
see "Cable cross-sections and
connections" in section
"Configuring instructions"
Dimensions
• Width
mm
350
350
350
350
350
• Height
(without mounting brackets)
mm
710
710
710
710
1060
• Depth
mm
320
320
320
320
320
Weight, approx.
kg
55
59
59
59
90
Approvals, according to
NRTL
7)
NRTL
7)
NRTL
7)
NRTL
7)
NRTL
7)
Frame size
K4
K4
K4
K4
K5
1)
Rated power of a typical 2- to 6-pole standard motor.
2)
Typical output voltage dependent on filter and unit type.
3)
Maximum power loss with continuous current.
4)
EMC filter not required for IT system, in which case RI suppression
category C4.
5)
Value is applicable with option L10 (strengthened d
v
/d
t
filter;
strengthened filter is integrated in unit).
6)
Value is applicable with option L10 (strengthened d
v
/d
t
filter;
strengthened filter is supplied separately with unit).
7)
On request; the voltage range for NRTL units ends at max. 600 V.
© Siemens AG 2014