Technical data
(continued)
400 V, 6-pulse
(continued)
Line voltage, supply system type
230 ... 500 V 3 AC, TT/TN
SINAMICS G180
compact units
6SE0100-
1AC32-5
■
A7
6SE0100-
1AC33-0
■
A7
Converter type
2T2A-07400-132
2T2A-07400-160
Electrical data at motor end
Type rating
1)
• at 50 Hz 400 V
kW
132
160
• at 60 Hz 460 V
hp
204
247
Output voltage
2)
V
0 ... 0.98 ×
V
line
0 ... 0.98 ×
V
line
Output current
• Continuous current
A
245
295
• Short-time current
(60 s every 10 minutes) max.
A
300
360
Overload capability
(60 s every 10 minutes) max.
%
22
22
Output power
kVA
170
204
Output frequency, max.
Hz
250
250
Rated clock cycle
kHz
3
3
adjustable from
kHz
2 ... 5
2 ... 5
Power loss
3)
kW
3.84
4.65
Rated efficiency
%
97.3
97.3
Electrical data at line end
Connected load
kVA
161
197
Rated input voltage
V
400
400
Input current
• Continuous line current
A
232
284
• Short-time line current (60 s)
max.
A
284
347
Line fuse
(provided by customer)
gL (A)
250 ... 315
315 ... 400
λ
line
0.924
0.924
Cos
ϕ
line
1
1
Radio interference suppres-
sion acc. to EN 61800-3
C2 (class A filter)
C2 (class A filter)
Mechanical data
Coolant requirements
m
3
/h
1600
1600
Sound pressure level
L
pA
(1 m) at 50/60 Hz
dB
66
66
Max. cable length between
converter and motor with
standard insulation
• on systems
≤
400 V (shielded)
m
200/350
4)
200/350
4)
• on systems > 400 V (shielded)
m
150/300
4)
150/300
4)
Line/load connection
L1, L2, L3/U2, V2, W2
For connection cross-sections,
see "Cable cross-sections and
connections" in section
"Configuring instructions"
Dimensions
• Width
mm
500
500
• Height
(without mounting brackets)
mm
1060
1060
• Depth
mm
320
320
Weight, approx.
kg
160
170
Approvals, according to
NRTL
5)
NRTL
5)
Frame size
K6
K6
1)
Rated power of a typical 2- to 6-pole standard motor.
2)
Typical output voltage dependent on filter and unit type.
3)
Maximum power loss with continuous current.
4)
Value is applicable with option L10 (strengthened d
v
/d
t
filter;
strengthened filter is integrated in unit).
5)
On request
© Siemens AG 2014