SINAMICS G180
Option descriptions
Standard options
4/12
Siemens D 18.1 · 2014
4
■
Options
(continued)
NAMUR-compliant assignment of inputs/outputs
The table below provides an overview of the pre-assignment
function of interfaces in the pin assignments for the "NAMUR"
application.
G05
Circuit diagram for peripheral board 4
Signal designation
Function
Internal digital input 17, 18
Forced power supply
disconnection
Internal digital input 19, 20
+24 V DC; forced inverter inhibit
Internal digital input 6
Rapid stop global 1
Internal digital input 7
Separately driven fan of motor
activated
Internal digital input 21
External fault
Internal digital input 22
External warning
Internal digital input 23
Operation, bus
Signal designation
Function
Internal digital input 24
Controller ON
Internal digital input 25
Fixed setpoint 1
Internal digital input 26
Fixed setpoint 2
Internal PTC thermistor
input 90, 91
PTC thermistor for disconnection
(ATEX-certified)
Internal PTC thermistor
input 92, 93
PTC thermistor for warning
Internal digital output 43, 44, 45
Relay 5: "Motor temperature trip"
Internal digital output 46, 47
Relay 6: "Automatic mode
(normal)"
Internal digital output 48, 49
Relay 7: "Speed 0"
Internal analog output 64, 65
Torque
Internal analog output 66, 67
Power
93
91
92
90
67
65
49
48
47
46
45
44
43
20
19
64
26
25
24
23
22
21
7
6
3
3
1
66
-X2:
5)
2)
4)
2)
2)
2)
2)
2)
2)
2)
2)
1)
3)
3)
X2:3
-X3:
G05
Peripheral board 4
Relay 7
Relay 6
Relay 5
Analog output 3
Digital outputs
Digital inputs
PTC thermistor
inputs
Digital input
(Safe Torque Off)
Analog output 4
Power
supply
0 …10 V or 0 (4)...20 mA
Trip
Prewarning
PTC inputs, suitable for motors in hazardous areas or non-hazardous areas
Remove the jumper if the connection terminals are used.
Remove the 100 Ω resistor if the connection terminals are used.
Four-way distribution terminal for 24 V
When peripheral board 3 / 4 are populated, the supply for digital inputs -X2:8 … 16 is
changed. -X2:1/3 is supplied in place of -X2:51/55.
1)
2)
3)
4)
5)
0 …10 V or 0 (4)...20 mA
PTC thermistor inputs
Safe isolation according to EN 61800-5-1 up to 690 V/
ATEX-certified for motors in the hazardous area only for -X3:90, 91
G_D024_EN_00008
250 V
Max. 1 A
AC 15
+24 V DC/max. 300 mA
M_DE
AO 3 X2: 64
AO 3 X2: 65
DI X2: 19
DI X2: 20
DI X2: 6
DI X2: 7
DI X2: 21
DI X2: 22
DI X2: 23
DI X2: 24
DI X2: 25
DI X2: 26
DO X2: 30
DO X2: 30
DO X2: 31
DO X2: 32
DO X2: 33
DO X2: 35
DO X2: 36
AO 4 X2: 66
AO 4 X2: 67
M_DE
M_DE
M_DE
M_DE
M_DE
M_DE
M_DE
M_DE
Typ.12 mA
M_ATV
M_DE