SIEMENS
SINAMICS G180
SINAMICS G180 cabinet units
SINAMICS G180 cabinet units
air-cooled and liquid-cooled
3/55
Siemens D 18.1 · 2014
3
■
Options
(continued)
Additional
ordering data
-Z
with order
code and, if
necessary,
with plain text
specification
Air-cooled and liquid-cooled versions of SINAMICS G180 cabinet units
400 V
500 V
690 V
Pulse number
6
12
6
12
6
12
18
24
Version – see selection and ordering data
Option text
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
Extension of the liability for defects
(continued)
Extension of the liability for defects by
36 months as of commissioning date or
by 48 months as of delivery date
Q84
Extension of the liability for defects by
48 months as of commissioning date or
by 60 months as of delivery date
Q85
Label for plant identification
Cabinet designation TAG/ITEM number
according to ordering data
T01
Customized labels
Y33
• and
identification
code
Ambient temperature for air-cooled converters
45 °C ambient temperature
(with corresponding derating)
V61
50 °C ambient temperature
(with corresponding derating)
V62
Water inlet temperature for liquid-cooled converters
30 °C water inlet temperature
(with corresponding derating)
V66
35 °C water inlet temperature
(with corresponding derating)
V67
40 °C water inlet temperature
(with corresponding derating)
V68
Installation altitude
Installation altitude max. 1500 m above
sea level (with corresponding derating)
V86
Installation altitude max. 2000 m above
sea level (with corresponding derating)
V87
Installation altitude max. 2500 m above
sea level (with corresponding derating)
V88
Installation altitude max. 3000 m above
sea level (with corresponding derating)
V89
Acceptance tests for converters
Routine test under no-load conditions
with customer present
F71
Routine test with 1PS or 1MD motor
(ordered with converter in package),
under no-load conditions (without
customer present)
F72
Routine test with 1PS or 1MD motor
(ordered with converter in package),
under no-load conditions with customer
present
F73
Visual inspection and function test under
rated load using test bay motor (without
customer present)
F80
Visual inspection and function test under
rated load using test bay motor with
customer present
F81
Visual inspection and function test under
rated load with 1PS or 1MD motor
(ordered with converter in package)
(without customer present)
F82
Visual inspection and function test under
rated load with 1PS or 1MD motor
(ordered with converter in package)
with customer present
F83
Advanced visual inspection and function
test under rated load with 1PS or 1MD
motor (ordered with converter in package)
(without customer present)
F84
For legends and footnotes, see Page 3/56.
© Siemens AG 2014