Options
The following tables provide an overview of the options and their availability for SINAMICS G180 cabinet units with a supply voltage
of 400 V, 500 V or 690 V. (For details, see catalog chapter 4 "Option descriptions".)
Additional
ordering data
-Z
with order
code and, if
necessary,
with plain text
specification
Air-cooled and liquid-cooled versions of SINAMICS G180 cabinet units
400 V
500 V
690 V
Pulse number
6
12
6
12
6
12
18
24
Version – see selection and ordering data
Option text
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
Line voltages
Line voltage 380 V, 50 Hz
V70
–
–
–
–
–
–
–
Line voltage 400 V, 50 Hz
V71
Line voltage 415 V, 50 Hz
V72
Line voltage 500 V, 50 Hz
V73
–
–
–
–
–
Line voltage 660 V, 50 Hz
V74
–
–
–
–
–
–
–
–
Line voltage 690 V, 50 Hz
V75
–
–
–
–
–
–
–
–
Line voltage 440 V, 60 Hz
V76
–
–
–
–
–
Line voltage 460 V, 60 Hz
V77
–
–
–
–
–
Line voltage 480 V, 60 Hz
V78
–
–
–
–
–
Line voltage 600 V, 60 Hz
V79
–
–
–
–
–
–
–
–
Line voltage 660 V, 60 Hz
V80
–
–
–
–
–
–
–
–
Special line voltage;
please specify voltage
Y70
• and
identification
code
1)
1)
1)
1)
1)
2)
2)
2)
3)
3)
3)
3)
3)
3)
3)
Additional cabinet
400 mm
H90
600 mm
H91
800 mm
H92
1000 mm
H93
1200 mm
H94
External auxiliary power supply
Connection for 230 V 1 AC 50 Hz
auxiliary voltage provided by customer
C36
Connection for 400 V 3 AC 50 Hz
auxiliary voltage provided by customer
C38
Connection for 500 V 3 AC 50 Hz
auxiliary voltage provided by customer
C43
Connection for 690 V 3 AC 50 Hz
auxiliary voltage provided by customer
C48
Connection for other 3 AC voltage
provided by customer;
please specify voltage
Y36
• and
identification
code
External control voltage supply
Connection for 230 V 1 AC 50 Hz
control voltage provided by customer,
without UPS backup
C56
Connection for 230 V 1 AC 50 Hz
control voltage provided by customer,
with UPS backup
C57
Connection for different 1 AC control
voltage (47 to 63 Hz) provided by
customer; please specify voltage
Y55
• and
identification
code
Other option
Board for mains supply backup
E85
RFI suppression filter
RFI suppression filter, category C2 or C3
(class A)
L00
–
–
–
Line Harmonics Filter
Line Harmonics Filter for 50 Hz
line frequency
L03
H92
6)
H92
6)
H93
6)
5)
–
H93
6)
5)
–
H92
6)
H93
6)
5)
H92
6)
H93
6)
5)
–
Line Harmonics Filter for 60 Hz
line frequency
L04
H92
6)
H92
6)
H93
6)
5)
–
H93
6)
5)
–
H92
6)
H93
6)
5)
H92
6)
H93
6)
5)
–