Technical data
(continued)
690 V, 24-pulse
(continued)
Line voltage, supply system type
4 × 400, 415, 460, 500, 575,
690
V 3 AC IT
SINAMICS G180
cabinet units – air-cooled
6SE0180-
4EH43-2
■
A7
6SE0180-
4EH43-6
■
A7
6SE0180-
4EH44-0
■
A7
6SE0180-
4HH44-3
■
A7
6SE0180-
4HH44-8
■
A7
Converter type
(air-cooled)
2T3L-87604-931
2T3L-87604-935
2T3L-87604-939
2T3L-87606-941
2T3L-87606-947
SINAMICS G180
cabinet units – liquid-cooled
6SE0170-
4EH43-2
■
A7
6SE0170-
4EH43-6
■
A7
6SE0170-
4EH44-0
■
A7
6SE0170-
4HH44-3
■
A7
6SE0170-
4HH44-8
■
A7
Converter type
(liquid-cooled)
2T6L-77604-931
2T6L-77604-935
2T6L-77604-939
2T6L-77606-941
2T6L-77606-947
Electrical data at motor end
Type rating
1)
• at 50 Hz 690 V
kW
3100
3500
3900
4100
4700
• at 60 Hz 575 V
hp
3465
3912
4359
4582
5253
Output voltage
2)
V
0 ... 0.98 ×
V
line
0 ... 0.98 ×
V
line
0 ... 0.98 ×
V
line
0 ... 0.98 ×
V
line
0 ... 0.98 ×
V
line
Output current
• Continuous current
A
3200
3610
3960
4290
4800
• Short-time current
(60 s every 10 minutes) max.
A
3730
4030
4300
5100
5610
Overload capability
(60 s every 10 minutes) max.
%
17
12
9
19
17
Output power
kVA
3824
4314
4732
5127
5736
Output frequency, max.
Hz
120
120
120
120
120
Rated clock cycle
kHz
2.4
2.4
2.4
2.4
2.4
adjustable from
kHz
1.5 ... 3.7
1.5 ... 3.7
1.5 ... 3.7
1.5 ... 3.7
1.5 ... 3.7
Power loss
3)
kW
77.3
87.3
99.7
102
110
Rated efficiency
%
97.7
97.7
97.6
97.7
97.8
Electrical data at line end
Connected load
kVA
3516
3956
4336
4692
5244
Rated input voltage
V
4 × 690
4 × 690
4 × 690
4 × 690
4 × 690
Input current
• Continuous line current
A
4 × 735
4 × 828
4 × 906
4 × 982
4 × 1098
• Short-time line current (60 s) max.
A
4 × 857
4 × 924
4 × 984
4 × 1167
4 × 1283
Line fuse (provided by customer)
gL (A)
900
1000
1000 ... 1250
1250
1250 ... 1500
λ
line
1
1
1
1
1
Cos
ϕ
line
1
1
1
1
1
Radio interference suppression
acc. to EN 61800-3
C4
C4
C4
C4
C4
Mechanical data for air-cooled cabinet units
Frame size
(dimensional drawing classification)
SL10
SL10
SL10
SL12
SL12
Sound pressure level
L
pA
(1 m) at 50/60 Hz
dB
79
79
79
79
79
Standard converter dimensions
• Width
mm
7206
7206
7206
11406
11406
• Height
4)
mm
2112
2112
2112
2112
2112
• Depth
mm
605
605
605
605
605
Coolant requirements
m
3
/h
12800
15200
15200
23150
19550
Weight, approx.
kg
3760
3970
4170
5750
5930
Mechanical data for liquid-cooled cabinet units
Frame size
(dimensional drawing classification)
SW10
SW10
SW10
–
5)
–
5)
Sound pressure level
L
pA
(1 m) at 50/60 Hz
dB
77
77
77
77
77
Standard converter dimensions
• Width
mm
7806
7806
7806
–
5)
–
5)
• Height
mm
2202
2202
2202
–
5)
–
5)
• Depth
mm
605
605
605
–
5)
–
5)
Coolant requirements
l/h
8000
8000
8000
12000
12000
Min. coolant pressure
bar
2.5
2.5
2.5
2.5
2.5
Max. coolant pressure
bar
6
6
6
6
6
Coolant test pressure
bar
10
10
10
10
10
Coolant pressure loss
bar
1.9
1.9
1.9
1.9
1.9
Min. coolant temperature
°C
10
10
10
10
10
Max. coolant temperature
°C
35
30
28
35
38
Weight, approx.
kg
3860
4070
4270
5910
6090
For footnotes, see next page.