SIEMENS
SINAMICS G180
SINAMICS G180 cabinet units
SINAMICS G180 cabinet units
air-cooled and liquid-cooled
3/38
Siemens D 18.1 · 2014
3
■
Technical data
(continued)
690 V, 18-pulse
Line voltage, supply system type
3 × 400, 415, 460, 500, 575,
690
V 3 AC IT
SINAMICS G180
cabinet units – air-cooled
6SE0180-
3DH42-2
■
A7
6SE0180-
3DH42-4
■
A7
6SE0180-
3DH42-7
■
A7
6SE0180-
3DH43-0
■
A7
6SE0180-
3HH44-3
■
A7
Converter type
(air-cooled)
2T3K-87603-920
2T3K-87603-923
2T3K-87603-926
2T3K-87603-929
2T3K-87606-941
SINAMICS G180
cabinet units – liquid-cooled
6SE0170-
3DH42-2
■
A7
6SE0170-
3DH42-4
■
A7
6SE0170-
3DH42-7
■
A7
6SE0170-
3DH43-0
■
A7
6SE0170-
3HH44-3
■
A7
Converter type
(liquid-cooled)
2T6K-77603-920
2T6K-77603-923
2T6K-77603-926
2T6K-77603-929
2T6K-77606-941
Electrical data at motor end
Type rating
1)
• at 50 Hz 690 V
kW
2000
2300
2600
2900
4100
• at 60 Hz 575 V
hp
2235
2570
2906
3241
4582
Output voltage
2)
V
0 ... 0.98 ×
V
line
0 ... 0.98 ×
V
line
0 ... 0.98 ×
V
line
0 ... 0.98 ×
V
line
0 ... 0.98 ×
V
line
Output current
• Continuous current
A
2140
2400
2710
2970
4290
• Short-time current
(60 s every 10 minutes) max.
A
2540
2800
3030
3230
5100
Overload capability
(60 s every 10 minutes) max.
%
19
17
12
9
19
Output power
kVA
2558
2868
3239
3549
5127
Output frequency, max.
Hz
120
120
120
120
120
Rated clock cycle
kHz
2.4
2.4
2.4
2.4
2.4
adjustable from
kHz
1.5 ... 3.7
1.5 ... 3.7
1.5 ... 3.7
1.5 ... 3.7
1.5 ... 3.7
Power loss
3)
kW
50.9
57.2
64.5
73.9
102
Rated efficiency
%
97.7
97.7
97.7
97.6
97.7
Electrical data at line end
Connected load
kVA
2369
2648
2983
3272
4692
Rated input voltage
V
3 × 690
3 × 690
3 × 690
3 × 690
3 × 690
Input current
• Continuous line current
A
3 × 661
3 × 739
3 × 832
3 × 912
3 × 1308
• Short-time line current (60 s) max.
A
3 × 785
3 × 862
3 × 930
3 × 992
3 × 1555
Line fuse (provided by customer)
gL (A)
800
900
1000
1250
1500
λ
line
1
1
1
1
1
Cos
ϕ
line
1
1
1
1
1
Radio interference suppression
acc. to EN 61800-3
C4
C4
C4
C4
C4
Mechanical data for air-cooled cabinet units
Frame size
(dimensional drawing classification)
SL7
SL7
SL7
SL7
SL11
Sound pressure level
L
pA
(1 m) at 50/60 Hz
dB
78
78
78
78
79
Standard converter dimensions
• Width
mm
4806
4806
4806
4806
10206
• Height
4)
mm
2112
2112
2112
2112
2112
• Depth
mm
605
605
605
605
605
Coolant requirements
m
3
/h
11400
9600
11400
11400
23150
Weight, approx.
kg
2750
2840
2990
3140
5750
Mechanical data for liquid-cooled cabinet units
Frame size
(dimensional drawing classification)
SW7
SW7
SW7
SW7
–
5)
Sound pressure level
L
pA
(1 m) at 50/60 Hz
dB
76
76
76
76
77
Standard converter dimensions
• Width
mm
5206
5206
5206
5206
–
5)
• Height
mm
2202
2202
2202
2202
–
5)
• Depth
mm
605
605
605
605
–
5)
Coolant requirements
l/h
6000
6000
6000
6000
12000
Min. coolant pressure
bar
2.5
2.5
2.5
2.5
2.5
Max. coolant pressure
bar
6
6
6
6
6
Coolant test pressure
bar
10
10
10
10
10
Coolant pressure loss
bar
1.9
1.9
1.9
1.9
1.9
Min. coolant temperature
°C
10
10
10
10
10
Max. coolant temperature
°C
35
35
30
28
35
Weight, approx.
kg
2830
2920
3070
3220
5910
For footnotes, see next page.
© Siemens AG 2014