SIEMENS
3/19
Siemens D 11 · 2015
■
Technical specifications
(continued)
3
SINAMICS G130
Drive converter chassis units
Power Modules
Note:
The power data in hp units is based on the NEC/CEC stan-
dards for the North American market.
1)
Rated output of a typical 6-pole standard induction motor based on
I
L
or
I
H
for 3 AC 50 Hz 640 V.
2)
The base-load current
I
L
is based on a load cycle of 110% for 60 s or 150%
for 10 s with a load cycle duration of 300 s
3)
The base-load current
I
L
is based on a load cycle of 150% for 60 s or 160%
for 10 s with a load cycle duration of 300 s
(
see Technical specifications
→
Overload capability
).
4)
N:\_Laufende_Aufträge\EM_LP_MK&CS_2_3\01_Kataloge\PI_3VA_FR_201
5\06_Korrekturläufe\04_Freigabe_Kunde\an_Kunde\3VA_gesamt_DRAFT
_2015-08-17.pdfIf the auxiliary supply is to be fed in separately from the
load supply, e.g. if the control should be able to continue communication
when the line voltage fails.
5)
The minimum current required to reliably trigger 3NE1 protective devices.
6)
The specified power losses are the maximum values for a utilization of
100%. The values are lower under normal operating conditions.
7)
Longer cable lengths for specific configurations are available on request.
Line voltage
660 ... 690 V 3 AC
Power Modules
6SL3310-
1GH28-5AA3
6SL3310-
1GH31-0AA3
6SL3310-
1GH31-2AA3
6SL3310-
1GH31-5AA3
6SL3310-
1GH31-8AA3
6SL3310-
1GH32-2AA3
Type rating
• For
I
L
at 50 Hz 690 V
1)
kW
75
90
110
132
160
200
• For
I
H
at 50 Hz 690 V
1)
kW
55
75
90
110
132
160
Output current
• Rated current
I
n
A
85
100
120
150
175
215
• Base-load current
I
L
2)
A
80
95
115
142
171
208
• Base-load current
I
H
3)
A
76
89
107
134
157
192
Input current
• Rated input current
A
93
109
131
164
191
224
• Input current, max.
A
131
155
188
232
279
341
•
Current requirement, 24 V DC auxiliary
power supply
4)
A
0.8
0.8
0.8
0.8
0.9
0.9
Minimum short-circuit current
5)
A
1050
1050
1200
1600
2400
3000
Heat loss, max.
6)
at 50 Hz 690 V
kW
1.3
1.6
1.8
2.3
3
3.5
Cooling air requirement
m
3
/s
0.17
0.17
0.17
0.17
0.36
0.36
Cable length, max.
between Power Module and motor
7)
• Shielded
m
300
300
300
300
300
300
• Unshielded
m
450
450
450
450
450
450
Degree of protection
IP20
IP20
IP20
IP20
IP20
IP20
Sound pressure level
L
pA
(1 m) at 50/60 Hz
dB
64/67
64/67
64/67
64/67
69/73
69/73
Line connection
U1, V1, W1
M10 screw
M10 screw
M10 screw
M10 screw
M10 screw
M10 screw
• Conductor cross section, max. (IEC)
mm
2
2 × 185
2 × 185
2 × 185
2 × 185
2 × 240
2 × 240
Motor connection
U2/T1, V2/T2, W2/T3
M10 screw
M10 screw
M10 screw
M10 screw
M10 screw
M10 screw
• Conductor cross section, max. (IEC)
mm
2
2 × 185
2 × 185
2 × 185
2 × 185
2 × 240
2 × 240
PE1/GND connection
M10 screw
M10 screw
M10 screw
M10 screw
M10 screw
M10 screw
• Conductor cross section, max. (IEC)
mm
2
2 × 185
2 × 185
2 × 185
2 × 185
2 × 240
2 × 240
PE2/GND connection
M10 screw
M10 screw
M10 screw
M10 screw
M10 screw
M10 screw
• Conductor cross section, max. (IEC)
mm
2
2 × 185
2 × 185
2 × 185
2 × 185
2 × 240
2 × 240
Dimensions
• Width
mm
326
326
326
326
326
326
• Height
mm
1400
1400
1400
1400
1533
1533
• Depth
mm
356
356
356
356
545
545
Weight, approx.
kg
104
104
104
104
176
176
Frame size
FX
FX
FX
FX
GX
GX
© Siemens AG 2015