SINAMICS G130
Drive converter chassis units
75 kW to 800 kW
dv/dt filter
compact plus VPL
No
Yes
Large reduction of the voltage
load on the motor winding
Large reduction of the voltage
load on the motor winding
dv/dt filter plus VPL
Yes
PROFINET IO connection
SINAMICS Link, EtherNet/IP
CAN bus connection
No
Yes
No
Yes
No
Safe actual value acquisition via
HTL/TTL encoder for Safety Integrated
Extended functions
Yes
No
Control of the Safety
Integrated extended functions
via F-DI/F-DO
Yes
No
Page
Page
Page
Page
Page
Measurement of the line or
motor voltage, flying restart
Yes
No
Speed measurement
Slight reduction
of the voltage load on the
motor winding
Motor reactor
Yes
No
Safe
Brake Control (SBC)
Connecting cable between SBA
and Control Interface Module
Yes
No
Yes
No
Temperature sensor
evaluation
Additional TM31 *
Yes
No
Yes
No
Note:
The use of an external 24 V supply must be checked for the components marked with *.
For further information, please refer to the SINAMICS Low Voltage Engineering Manual.
Interface expansion
with DI/DO and AI/AO
Interface expansion
with DI/DO and AI/AO
Operator panel for Control Unit
Operator panel for cabinet mounting
Interface expansion
with DI/DO and AI/AO
Installation acc. to EN 61800-3
1st environment
Serial plug-in cable
pre-assembled
x meters
DRIVE-CLiQ cable
pre-assembled
x meters
DRIVE-CLiQ cable
pre-assembled
x meters
DRIVE-CLiQ cable
pre-assembled
x meters
DRIVE-CLiQ cable
pre-assembled
x meters
DRIVE-CLiQ cable
pre-assembled
x meters
DRIVE-CLiQ cable
pre-assembled
x meters
DRIVE-CLiQ cable
pre-assembled
x meters
Yes
2nd SMC30 *
SBA Safe Brake Adapter, 230 V AC
TB30 Terminal Board
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Control Unit and Control Unit Kit CU320-2
CompactFlash card
Line filter
No
Yes
Switching/disconnecting
element
Switching/disconnecting
element
Current > 800 A
Line reactor
No
Yes
Line Harmonics
Filter
Slight reduction of low-
frequency line harmonic distortions
Large reduction of low-
frequency line harmonic distortions
Configuration start
G_D011_EN_00129d
Configuration end
Braking resistor
Power
switch
Contactor
Fuses
Yes
No
No
No
Yes
No
Yes
Fuse-switch disconnector
Braking Module
Braking operation required
Infeed of almost
sinusoidal voltage at the motor
Sine-wave filter
3/69
Power Module 6SL3310-1G...-.AA3
CBC10 *
CBE20 *
BOP20
AOP30
TM31 *
TM150 *
SMC30 *
VSM10 *
TM54F *
1
1
3/71
3/66
3/76
3/76
3/75
3/73
3/73
3/37
3/41
3/46
3/50
3/32
3/35
3/76
3/76
3/63
3/76
3/57
3/56
3/60
3/59
3/61
3/55
3/52
3/21
3/30
3/26
3/24
3/13
3/30
3/30
3/31
3/63
3/76
3/76
3/76
3/75
© Siemens AG 2015