SINAMICS G150
Drive converter cabinet units
75 kW to 2700 kW
Technical specifications for parallel connection
Note:
The power data in hp units is based on the NEC/CEC standards for the North American market.
For information on the line connection, motor connection and cabinet grounding, see Section Configuration.
SINAMICS G150 converter cabinet units,
version A
6SL3710-2GE..-
....
SINAMICS G150 converter cabinet units,
version A
6SL3710-2GF..-
....
Parallel connection
41-1AA3
41-4AA3
41-6AA3
38-6AA3
41-1AA3
41-4AA3
Line voltage
380 ... 480 V 3 AC
500 ... 600 V 3 AC
Type rating
• For
I
L
1)
kW
630
710
900
630
710
1000
• For
I
H
1)
kW
500
560
710
560
630
800
• For
I
L
at 60 Hz 460 V
or 575 V
2)
hp
900
1000
1250
900
1000
1250
• For
I
H
at 60 Hz 460 V
or 575 V
2)
hp
700
900
1000
800
900
1000
Output current
• Rated current
I
n
3)
A
1120
1380
1560
860
1070
1360
• Base-load current
I
L
3)4)
A
1092
1340
1516
836
1036
1314
• Base-load current
I
H
3)5)
A
850
1054
1294
770
950
1216
Input current
• Rated input current
3)6)
A
1174
1444
1624
904
1116
1424
• Input current, max.
A
1800
2215
2495
1388
1708
2186
• Current requirement, 24 V DC
auxiliary power supply
7)
A
2.8
2.8
3
2.8
2.8
3
Rated short-circuit current
according to IEC
8)
kA
2 × 65
2 × 65
2 × 65
2 × 65
2 × 65
2 × 84
Minimum
short-circuit current
9)
A
2 × 1000
2 × 10500
2 × 1800
2 × 6200
2 × 8400
2 × 10500
Power loss, max.
10)
• At 50 Hz 400 V / 500 V
kW
16.2
19
19.9
15.4
17.2
23.8
• At 60 Hz 460 V / 575 V
kW
16.6
19.4
20.4
15
16.8
25
Cooling air requirement
m
3
/s
1.56
1.56
1.56
1.56
1.56
2.96
Sound pressure level
L
pA
(1 m) at 50/60 Hz
dB
73/76
73/76
73/76
75/78
75/78
75/78
Cable lengths
between converter and motor
11)
• Shielded
m
300
300
300
300
300
300
• Unshielded
m
450
450
450
450
450
450
Dimensions
• Width
12)
mm
2400
2400
2400
2400
2400
3200
• Height
13)
mm
2000
2000
2000
2000
2000
2000
• Depth
mm
600
600
600
600
600
600
Weight, approx.
(degree of protection IP20,
without options)
kg
1700
1710
2130
1700
1700
2620
1)
Rated output of a typical 6-pole standard induction motor based on
I
L
or
I
H
for 3 AC 50 Hz 400 V, 500 V or 690 V.
2)
Rated output of a typical 6-pole standard induction motor based on
I
L
or
I
H
for 3 AC 60 Hz 460 V or 575 V.
3)
The currents listed here are the aggregate current of the two converter
sections.
4)
The base-load current
I
L
is based on a load cycle of 110% for 60 s or 150%
for 10 s with a load cycle duration of 300 s.
See Characteristic curves,
Section Overload capability.
5)
The base-load current
I
H
is based on a duty cycle of 150% for 60 s or
160% for 10 s with a duty cycle duration of 300 s.
See Characteristic
curves, Section Overload capability.
6)
The currents listed here are based on the rated output current.
7)
If the drive control is to remain active after a main infeed failure, the converter
must be externally supplied with 24 V DC.
The following must also be taken into account:
– CU320-2: 1 A
– TM31: 0.5 A
– AOP30: 0.2 A
– SMC: 0.6 A
– Current requirement of digital inputs/outputs.
8)
In conjunction with the specified fuses or circuit breakers.
9)
Minimum current required for reliably triggering the protective devices.
10)
The specified power losses are the maximum values for a utilization of
100%. The values are lower under normal operating conditions.
11)
Longer cable lengths for specific configurations are available on request.
12)
Power units connected in parallel are shipped as two transport units.
13)
Version A:
The cabinet height increases by
– 250 mm for degree of protection IP21
– 400 mm for degrees of protection IP23, IP43 and IP54
– 405 mm for options
M13
and
M78
© Siemens AG 2015