Technical specifications
(continued)
4
SINAMICS G150
Drive converter cabinet units
75 kW to 2700 kW
Note:
The power data in hp units is based on the NEC/CEC standards for the North American market.
For information on the line connection, motor connection and cabinet grounding, see Section Configuration.
Line voltage
660 ... 690 V 3 AC
SINAMICS G150 converter cabinet units
6SL3710-1GH..-
....
Single connection
28-5.A3
31-0.A3
31-2.A3
31-5.A3
31-8.A3
32-2.A3
32-6.A3
Type rating
• For
I
L
at 50 Hz 690 V
1)
kW
75
90
110
132
160
200
250
• For
I
H
at 50 Hz 690 V
1)
kW
55
75
90
110
132
160
200
Output current
• Rated current
I
n
A
85
100
120
150
175
215
260
• Base-load current
I
L
2)
A
80
95
115
142
171
208
250
• Base-load current
I
H
3)
A
76
89
107
134
157
192
233
Input current
• Rated input current
4)
A
93
109
131
164
191
224
270
• Input current, max.
A
131
155
188
232
279
341
410
• Current requirement, 24 V DC
auxiliary power supply
5)
A
1.1
1.1
1.1
1.1
1.35
1.35
1.35
Rated short-circuit current
according to IEC
6)
kA
65
65
65
65
65
65
65
Minimum
short-circuit current
7)
A
1500
1500
1200
1600
2400
3000
3600
Power loss, max.
8)
at 50 Hz 690 V
kW
1.7
2.1
2.7
2.8
3.8
4.2
5
Cooling air requirement
m
3
/s
0.17
0.17
0.17
0.17
0.36
0.36
0.36
Sound pressure level
L
pA
(1 m) at 50/60 Hz
dB
67/68
67/68
67/68
67/68
67/73
67/73
67/73
Cable lengths
between converter and motor
9)
• Shielded
m
300
300
300
300
300
300
300
• Unshielded
m
450
450
450
450
450
450
450
Dimensions
• Width for
version A/C
mm
800/400
800/400
800/400
800/400
800/400
800/400
800/400
• Height
10)
mm
2000
2000
2000
2000
2000
2000
2000
• Depth
mm
600
600
600
600
600
600
600
Weight, approx.
(degree of protection IP20,
without options) for version A/C
kg
460/225
460/225
460/225
460/225
670/300
670/300
670/300
1)
Rated output of a typical 6-pole standard induction motor based on
I
L
or
I
H
for 3 AC 50 Hz 400 V.
2)
The base-load current
I
L
is based on a load cycle of 110% for 60 s or
150% for 10 s with a load cycle duration of 300 s.
See Characteristic
curves, Section Overload capability.
3)
The base-load current
I
H
is based on a duty cycle of 150% for 60 s or
160% for 10 s with a duty cycle duration of 300 s.
See Characteristic
curves, Section Overload capability.
4)
The currents listed here are based on the rated output current.
5)
If the drive control is to remain active after a main infeed failure, the converter
must be externally supplied with 24 V DC.
The following must also be taken into account:
– CU320-2: 1 A
– TM31: 0.5 A
– AOP30: 0.2 A
– SMC: 0.6 A
– Current requirement of digital inputs/outputs.
6)
In conjunction with the specified fuses or circuit breakers.
7)
Minimum current required for reliably triggering the protective devices.
8)
The specified power losses are the maximum values for a utilization of
100%. The values are lower under normal operating conditions.
9)
Longer cable lengths for specific configurations are available on request.
10)
Version A:
The cabinet height increases by
– 250 mm for degree of protection IP21
– 400 mm for degrees of protection IP23, IP43 and IP54
– 405 mm for options
M13
and
M78
Version C:
The cabinet height increases by
– 250 mm for degree of protection IP21
– 400 mm for degrees of protection IP23, IP43 and IP54