SINAMICS G150
Drive converter cabinet units
75 kW to 2700 kW
■
Options
When ordering a converter with options, add the suffix
"-Z"
to the
article number and then the order code(s) for the desired op-
tion(s).
Example:
6SL3710-1GE32-1CA3-Z
+M07+D60+...
See also ordering examples.
Available options
Order code
Version A
Version C
Input-side options
Use in the first environment according to EN 61800-3
Category C2 (TN systems or TT systems with grounded neutral point)
1)
L00
–
Clean Power version with integrated Line Harmonics Filter compact
2)
L01
–
Line contactor (for currents
≤
800 A for single connection)
L13
–
Surge suppression
L21
–
Scope of delivery without line reactor (for converters
≤
500 kW)
L22
Line reactor
u
k
= 2% (for converters > 500 kW)
L23
Main switch incl. fuses or circuit breakers
L26
–
Quick start (for option
L01
)
L76
–
EMC shield bus
3)
(cable connection from below)
M70
PE busbar
3) 4)
(cable connection from below)
M75
–
Output-side options
dv/dt filter compact plus Voltage Peak Limiter
L07
–
Motor reactor
L08
–
dv/dt filter plus Voltage Peak Limiter
2)
L10
–
Sine-wave filter (up to 250 kW at 380 ... 480 V, up to 132 kW at 500 ... 600 V)
L15
–
EMC shield bus
3)
(cable connection from below)
M70
PE busbar
3) 4)
(cable connection from below)
M75
–
Motor protection and safety functions
EMERGENCY OFF pushbutton installed in the cabinet door
L45
–
EMERGENCY OFF Category 0, 230 V AC or 24 V DC
L57
–
EMERGENCY STOP Category 1, 230 V AC
5)
L59
–
EMERGENCY STOP Category 1, 24 V DC
5)
L60
–
Thermistor motor protection (alarm)
L83
–
Thermistor motor protection (trip)
L84
–
Pt100 evaluation unit
L86
–
Insulation monitoring
L87
–
Degree of protection increase
Degree of protection IP21
M21
Degree of protection IP23
M23
Degree of protection IP43
M43
Degree of protection IP54
M54
Mechanical options
Base 100 mm high, RAL 7022
M06
Cable-marshaling compartment 200 mm high, RAL 7035
M07
Line connection from above
2)
M13
–
Motor connection from above
2)
M78
–
Crane transport assembly (top-mounted)
M90
Option can be ordered
–
Option cannot be ordered
Please refer to the selection matrix for information about possible option combinations.
2)
Applies to motor cable lengths < 100 m.
3)
Not available for converters > 1500 kW with power units connected in
parallel.
4)
This option is listed for the input- and output-side options, but is only
required once.
5)
This option is contained as standard in version A.
6)
The stopping requirements must be taken into account with this option. Addi-
tional braking units may be required.