SIEMENS
4/28
Siemens D 35 · 2017
■
Dimensional drawings
(continued)
4
SINAMICS G120P built-in and wall-mounted units
PM230 Power Modules, 0.37 kW to 90 kW
PM230 Power Modules
PM230 Power Modules, degree of protection IP20, Standard variant
Principle dimension drawing and drill pattern for PM230 Power Modules, degree of protection IP20, Standard variant,
with/without integrated line filter class A
Frame size
Dimensions
in mm
(inches)
Drilling dimensions
in mm
(inches)
Cooling clearance
in mm
(inches)
Mounting
a
(width)
b
(height)
c
(depth)
1)
d
e
f
top
bottom
side
2)
With bolts
PM230 Power Modules, degree of protection IP20, Standard variant, with/without integrated line filter class A
FSA
73
(2.87)
196
(7.72)
165
(6.5)
62.3
(2.45)
186
(7.32)
6
(0.24)
80
(3.15)
100
(3.94)
0
(0)
3 × M4
FSB
100
(3.94)
292
(11.5)
165
(6.5)
80
(3.15)
281
(11.06)
6
(0.24)
80
(3.15)
100
(3.94)
0
(0)
4 × M4
FSC
140
(5.51)
355
(13.98)
165
(6.5)
120
(4.72)
343
(13.5)
6
(0.24)
80
(3.15)
100
(3.94)
0
(0)
4 × M5
FSD
275
(10.83)
419/512
(16.50/20.16)
204
(8.03)
235
(9.25)
325/419
(12.8/16.5)
11
(0.43)
300
(11.81)
300
(11.81)
0
(0)
4 × M6
FSE
275
(10.83)
499/635
(19.65/25)
204
(8.03)
235
(9.25)
405/541
(15.94/21.3)
11
(0.43)
300
(11.81)
300
(11.81)
0
(0)
4 × M6
FSF
350
(13.78)
634/934
(24.96/36.77)
316
(12.44)
300
(11.81)
598/899
(23.54/35.39)
11
(0.43)
350
(13.78)
350
(13.78)
0
(0)
4 × M8
d
e
f
f
d
a
c
e
G_D011_EN_00388
Drill
pattern
FSA
b
Drill pattern
FSB - FSF
1)
Increased depth:
• When the CU230P-2 Control Unit is plugged on, the depth increases by 58 mm
(2.28 in)
for FSA to FSC and by 49 mm
(1.93 in)
for FSD to FSF
• When the IOP is plugged on, the depth increases by a further 22 mm
(0.87 in)
• When the BOP-2 is plugged on, the depth increases by a further 12 mm
(0.47 in)
2)
The Power Modules can be mounted side by side. A side clearance of 1 mm
(0.04 in)
is recommended for tolerance-related reasons.
© Siemens AG 2017