SIEMENS
4/15
Siemens D 35 · 2017
4
SINAMICS G120P built-in and wall-mounted units
PM230 Power Modules, 0.37 kW to 90 kW
PM230 Power Modules
■
Technical specifications
General technical specifications
PM230 Power Modules
Degree of protection
IP55 (with BOP-2 or blanking cover)
IP54 with IOP
IP20/UL Open Type
(Standard or Push Through variants)
Power (low overload LO)
0.37 ... 90 kW
0.37 ... 75 kW
Rated output current (low overload LO)
1.3 ... 178 A
1.3 ... 145 A
Power (high overload HO)
0.25 ... 75 kW
0.25 ... 55 kW
Rated output current
(high overload HO)
0.9 ... 145 A
0.9 ... 110 A
System operating voltage
380 ... 480 V ±10 % 3 AC
Grid requirement
Short-circuit power R
SC
>100
Input frequency
47 ... 63 Hz
Output frequency
• Control mode V/f
0 ... 550 Hz
• Control type Vector
0 ... 240 Hz
Pulse frequency
4 kHz
for higher pulse frequencies up to 16 kHz,
see derating data
Power factor
λ
0.9
Offset factor cos
ϕ
0.95
Inverter efficiency
≤
97 %
Output voltage, max.
as % of input voltage
95 %
Overload capability
• Low overload (LO)
Note:
When the overload capability is used, the base-load current
I
L
is not reduced.
-
Frame sizes FSA to FSC
1.5 × base-load current
I
L
(i. e. 150 % overload) for 3 s
plus
1.1 × base-load current
I
L
(i. e. 110 % overload) for 57 s within a cycle time of 300 s
-
Frame sizes FSD to FSF
1.1 × base-load current
I
L
(i. e. 110 % overload) for 60 s within a cycle time of 300 s
• High overload (HO)
Note:
When the overload capability is used, the base-load current
I
H
is not reduced.
-
Frame sizes FSA to FSC
2 × base-load current
I
H
(i. e. 200 % overload) for 3 s
plus
1.5 × base-load current
I
H
(i. e. 150 % overload) for 57 s within a cycle time of 300 s
-
Frame sizes FSD to FSF
1.5 × base-load current
I
H
(i. e. 150 % overload) for 60 s within a cycle time of 300 s
Electromagnetic compatibility
•
Devices with line filter class
A for applications according
to Categories C3 and C2
•
Devices with line filter class
B for applications according
to Category C2 and compliance with conducted interfer-
ence requirements of Category C1
• Devices without line filter
•
Devices with line filter class
A for applications according
to Categories C3 and C2
•
Devices with line filter class
B for applications according
to Category C2 and compliance with conducted interfer-
ence requirements of Category C1
Possible braking methods
DC braking
Operating temperature
• Low overload (LO)
Frame sizes FSA to FSC: -10 ... +40 °C (14 ... 104 °F) without derating
Frame sizes FSD to FSF: 0 ... 40 °C (32 ... 104 °F) without derating
>40 ... 60 °C (104 ... 140 °F)
see derating characteristics
• High overload (HO)
Frame sizes FSA to FSC: -10 ... +50 °C (14 ... 122 °F) without derating
Frame sizes FSD to FSF: 0 ... 50 °C (32 ... 122 °F) without derating
>50 ... 60 °C (122 ... 140 °F)
see derating characteristics
Relative humidity
<95 %, condensation not permissible
Storage temperature
-40 ... +70 °C (-40 ... +158 °F)
Cooling
Power units with increased air cooling using integrated fans
Installation altitude
Up to 1000 m (3281 ft) above sea level without derating,
> 1000 m (3281 ft)
see derating characteristics
Protection functions
• Undervoltage
• Overvoltage
• Overcurrent/overload
• Overtemperature
• Ground fault
• Short-circuit
• Stall protection
• Motor blocking protection
• Motor overtemperature
• Inverter overtemperature
• Parameter locking
Rated short-circuit current SCCR
(Short-Circuit Current Rating)
1)
Frame sizes FSA to FSC: 40 kA
65 kA
Compliance with standards
UL
2)
, cUL
3)
, CE, RCM, SEMI F47
CE marking
According to Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU
1)
Applies to industrial control panel installations acc. to NEC Article 409 or
UL 508A/508C.
2)
For degree of protection IP55/UL Type 12, the UL approval only applies to
frame sizes FSA to FSC.
3)
Applies to PM230 Power Modules, frame sizes FSA to FSC.
© Siemens AG 2017