SIEMENS
3/28
Siemens D 35 · 2017
■
Overview
(continued)
3
System configuration
SINAMICS G120P and SINAMICS G120P Cabinet pump, fan, compressor converters
Integrated Drive Systems
SINAMICS G120P Power Modules for use in water/wastewater applications and in industrial environments,
with degree of protection IP20, 500 to 690 V 3 AC
SINAMICS G120P
Rated power
1)
Rated
output
current
I
rated
2)
Power based on the
base-load current
I
H
3)
Base-load
current
I
H
3)
Power Module
690 V
575 V
690 V
575 V
Frame size
Type
Without
integrated line
filter
With
integrated line filter
class A (Category C2
4)
)
kW
hp
A
kW
hp
A
Article No.
Article No.
11
10
14
7.5
8
11
FSD
PM240P-2
6SL3210-1RH21-4UL0
6SL3210-1RH21-4AL0
15
15
19
11
10
14
6SL3210-1RH22-0UL0
6SL3210-1RH22-0AL0
18.5
20
23
15
15
19
6SL3210-1RH22-3UL0
6SL3210-1RH22-3AL0
22
25
27
18.5
20
23
6SL3210-1RH22-7UL0
6SL3210-1RH22-7AL0
30
30
35
22
25
27
6SL3210-1RH23-5UL0
6SL3210-1RH23-5AL0
37
40
42
30
30
35
6SL3210-1RH24-2UL0
6SL3210-1RH24-2AL0
45
50
52
37
40
42
FSE
6SL3210-1RH25-2UL0
6SL3210-1RH25-2AL0
55
60
62
45
50
52
6SL3210-1RH26-2UL0
6SL3210-1RH26-2AL0
75
75
80
55
60
62
FSF
6SL3210-1RH28-0UL0
6SL3210-1RH28-0AL0
90
100
100
75
75
80
6SL3210-1RH31-0UL0
6SL3210-1RH31-0AL0
110
100
115
90
100
100
6SL3210-1RH31-2UL0
6SL3210-1RH31-2AL0
132
125
142
110
100
115
6SL3210-1RH31-4UL0
6SL3210-1RH31-4AL0
315
350
340
250
250
272
HX
PM330
6SL3310-1PG33-7AA0
–
355
400
393
315
300
314
6SL3310-1PG34-0AA0
–
400
450
430
355
350
348
6SL3310-1PG34-5AA0
–
450
450
480
400
450
394
6SL3310-1PG35-2AA0
–
500
500
535
450
450
444
JX
6SL3310-1PG35-8AA0
–
560
600
595
500
500
476
6SL3310-1PG36-5AA0
–
630
700
665
560
500
532
6SL3310-1PG37-2AA0
–
1)
PM240P-2
:
Rated power based on the rated output current
I
rated
. The
rated output current
I
rated
is based on the duty cycle for low overload
(LO). PM330
: Rated power based on the base-load current
I
L
. The
base-load current
I
L
is based on the duty cycle for low overload (LO).
2)
PM240P-2
:
The rated output current
I
rated
is based on the duty cycle
for low overload (LO). These current values are valid for 690 V and are
specified on the rating plate of the Power Module.
3)
The base-load current
I
H
is based on the duty cycle for
high overload (HO)
4)
PM240P-2
:
The Power Modules in frame size FSF with integrated line
filter comply with radio interference category C3 according to
EN 61800-3.
© Siemens AG 2017