SIEMENS
3/13
Siemens D 35 · 2017
■
Technical specifications
(continued)
3
System configuration
SINAMICS G120P and SINAMICS G120P Cabinet pump, fan, compressor converters
SINAMICS G120P and SINAMICS G120P Cabinet pump, fan, compressor converters
SEMI F47
SEMI F47 is an industry standard relating to the immunity to volt-
age dips. This includes the requirement that industrial equip-
ment must be able to tolerate defined dips or drops of the line
supply voltage. As a result, industrial equipment that fulfills this
standard is more reliable and productive.
All Power Modules of the SINAMICS G120P product family fulfill
the latest standard SEMI F47-0706
1)
. In the case of a voltage
dip, defined in accordance with SEMI F47-0706, these drives
either continue to supply a defined output current, or using an
automatic restart function, continue to operate as expected.
EAC approval for Russia/Belarus/Kazakhstan/Armenia
Since February 15, 2013, Russia, Kazakhstan, Belarus and
Armenia have been united in the Eurasian EAC customs union.
An EAC approval as replacement for the GOST mark is required
for all products that are to be sold in Russia.
All devices delivered to the customs union must have these cus-
toms certifications.
RCM approval for Australia
The RCM mark is required for marketing Siemens components in
Australia. Electronic devices must provide proof of EMC clear-
ance in Australia, similar to the CE marking of conformity laid
down by the EMC directive applicable in the EU. The converters
must be marked accordingly. These requirements have been in
force since October 1, 1999.
On March 1, 2016, the C-Tick mark was replaced by the
RCM mark.
KC approval for South Korea
KC approval (formerly KCC) is required for the distribution of our
electrical equipment in South Korea. Electronic devices that are
covered by the EU Directive on Electromagnetic Compatibility
must provide an EMC certificate issued by a resident authority in
South Korea. The devices must be marked accordingly. This re-
quirement has been in force since January 24, 2011.
Power Modules
General technical specifications
1)
SEMI F47 for PM330 Power Modules frame size HX (500 V to 690 V) and JX
available soon.
2)
Does not apply in conjunction with option
L01
.
Power Modules
PM230
PM240P-2
PM330
Cabinet
System operating voltage
380 ... 480 V ±10 % 3 AC
380 ... 480 V 3 AC ±10 %
500 ... 690 V 3 AC ±10 %
380 ... 480 V 3 AC ±10 %
500 ... 690 V 3 AC ±10 %
380 ... 480 V 3 AC ±10 %
500 ... 690 V 3 AC ±10 %
Grid requirement
Short-circuit power R
SC
>100
>25
>33 line reactor recom-
mended
>33
2)
Line reactors
installed as standard
Input frequency
47 ... 63 Hz
47 ... 63 Hz
47 ... 63 Hz
47 ... 63 Hz
Output frequency
• Control mode V/f
0 ... 550 Hz
0 ... 550 Hz
0 ... 150 Hz
0 ... 150 Hz
• Control type Vector
0 ... 240 Hz
0 ... 200 Hz
0 ... 150 Hz
0 ... 150 Hz
Pulse frequency
4 kHz
Higher pulse frequencies
up to 16
kHz,
see derating
data
At 380 ... 480 V 3 AC:
Up to 90 kW
LO: 4 kHz
From 110 kW
LO: 2 kHz
Higher pulse frequencies
up to 16 kHz,
see derating
data
At 500 ... 690 V 3 AC:
2 kHz, can be adjusted to
4 kHz
Self-adjusting up to 4 kHz
Self-adjusting up to 4 kHz
Power factor
λ
0.9
0.9 ... 0.95
0.75 ... 0.93
0.75 ... 0.93
Offset factor cos
ϕ
0.95
0.99
0.96
0.96
Efficiency
≤
97 %
>97 %
>98 %
>98 %
Output voltage, max.
As % of input voltage
95 %
95 %
97 %
97 %
© Siemens AG 2017