SIEMENS
3/11
Siemens D 35 · 2017
■
Technical specifications
(continued)
3
System configuration
SINAMICS G120P and SINAMICS G120P Cabinet pump, fan, compressor converters
SINAMICS G120P and SINAMICS G120P Cabinet pump, fan, compressor converters
Note:
The EMC product standard EN 61800-3 does not apply directly
to a frequency converter but to a PDS (Power Drive System),
which comprises the complete circuitry, motor and cables in
addition to the converter. The frequency converters on their
own do not generally require identification according to the
EMC Directive.
Standards
Compliance with standards
• Drives and components, frame sizes FSA to FSF
UL
1)
, cUL
2)
, CE, RCM, SEMI F47
• Drives, frame sizes GX to JX
cULus, CE, RCM, EAC, KC, SEMI F47
3)
• SINAMICS G120P Cabinet
CE, RCM, EAC, KC, SEMI F47
3)
CE marking
According to Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU
EMC Directive
According to EN 61800-3
• PM230: Frame sizes FSA to FSF with integrated line filter
class A, degree of protection IP20/UL Open Type and
IP55/UL Type 12
The Power Modules comply with Category C2 according to EN 61800-3.
• PM230: Frame sizes FSA to FSF with integrated line filter
class B, degree of protection IP55/UL Type 12
The Power Modules comply with the limit values for low-frequency line harmonics and conducted
interference according to Category C1. They comply with the limit values for field-conducted inter-
ference emissions according to Category C2.
• PM240P-2: Frame sizes FSD to FSF (380 ... 480 V 3 AC)
with integrated line filter class A
The Power Modules comply with Category C2 according to EN 61800-3.
• PM240P-2: Frame size FSF (500 ... 690 V 3 AC)
with integrated line filter class A
The Power Modules comply with Category C3 according to EN 61800-3.
• PM330: Frame sizes GX to JX
Category C3
4)
• PM330: Frame sizes GX to JX with additional line filter
class A
Category C2
5)
• SINAMICS G120P Cabinet
Category C3
6 )
• SINAMICS G120P Cabinet with additional line filter
class A
Category C2
6)
1)
For degree of protection IP55/UL Type 12, the UL approval only applies to
frame sizes FSA to FSC.
2)
Applies to PM230 Power Modules frame sizes FSA to FSC and PM240P-2
Power Modules with integrated line filter class A.
3)
SEMI F47 for PM330 Power Modules, frame sizes HX (500 V to 690 V) and
JX, available soon.
4)
Standard configuration: Devices installed in the control cabinet with
EMC-compatible configuration, line reactor u
K
= 2 %, shielded motor
cable (e.g. Protoflex EMC) with max. 150 m cable length. Line harmonics
acc. to EN 61000-2-4: Class 3, THD(U) total = 10 % for typical line condi-
tions (RSC > 10); THD(I) total: typically 30 ... 45 % (15 > RSC > 50).
5)
Use in the second environment,
for boundary conditions refer to
4)
.
6)
For boundary conditions refer to
4)
, cabinet is configured accordingly in
version A.
© Siemens AG 2017